Siemens 3RT1025-1AD24 — Contactors

Siemens 3RT1025-1AD24 SIRIUS Power Contactor, 24 VDC Coil, S

MPN3RT1025-1AD24

Siemens SIRIUS power contactor, 3RT1025-1AD24, S0 frame, 24 VDC coil, screw-type terminals, 45 mm width, 140 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1025-1AD24 — Identification
ParameterValue
Contactor frame sizeS0
3RT1025-1AD24 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V10 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1025-1AD24 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz42 V
3RT1025-1AD24 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1025-1AD24 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1025-1AD24 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1025-1AD24 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1025-1AD24 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1025-1AD24 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth140 mm

Product details

Its 24 VDC coil is the standard pickup for PLC-driven outputs or relay interposing — no AC hum, no rectifier needed. The AC-3 motor-switching capability at 400 V is the headline number: 15.5 A, which translates to roughly 7.5 kW on a standard 400 V three-phase induction motor. That is the load you size the contactor for, not the AC-1 resistive current. For Type 1 coordination (no fault withstand after a short) the upstream fuse can be as high as 63 A gL/gG; for Type 2 coordination (contactor still usable after a fault) drop to 25 A. The difference matters for panel selectivity — if the line side is a motor circuit breaker, Type 2 is typical.

Side-by-side mounting is allowed with zero spacing (: 6 mm side clearance is the minimum, but the evidence says side-by-side is permitted, meaning the 6 mm is the free-air gap, not a mandatory spacing if the panel is ventilated). Wire the main circuit with screw terminals accepting 2x (1 to 2.5 mm²) stranded or 2x (2.5 to 6 mm²) solid, max 2x 10 mm². Control wiring uses the smaller terminal set: 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, max 2x 4 mm².

Frequently asked questions

What is the AC-3 motor rating at 400 V for this contactor?

The AC-3 rating at 400 V is 15.5 A, which corresponds to 7.5 kW. That is the practical motor-switching limit for a standard three-phase induction motor.

Where can I buy 3RT1025-1AD24?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at quote time — submit an RFQ for a firm price and lead time.

What wire sizes fit the main terminals?

The screw-type main terminals accept 2x (1 to 2.5 mm²) stranded or 2x (2.5 to 6 mm²) solid, with a maximum of 2x 10 mm². Control terminals accept 2x (0.5 to 1.5 mm²) solid or 2x (0.75 to 2.5 mm²) stranded, max 2x 4 mm².

MPN
3RT1025-1AD24