Siemens 3RT1025-1AP00-1AA0 — Contactors

Siemens 3RT1025-1AP00-1AA0 SIRIUS Power Contactor, S0, 3 NO,

MPN3RT1025-1AP00-1AA0

Siemens SIRIUS 3RT1025-1AP00-1AA0 power contactor, size S0, 3 NO main contacts, screw terminals, 15.5 A AC-4 at 400 V, 11 kW at 690 V, 50 Hz, DIN rail mount, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1025-1AP00-1AA0 — Identification
ParameterValue
Contactor frame sizeS0
3RT1025-1AP00-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V10 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1025-1AP00-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1025-1AP00-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1025-1AP00-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 63 A
Short-circuit coordination type 2, fusefuse gL/gG: 25 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1025-1AP00-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1025-1AP00-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1025-1AP00-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1025-1AP00-1AA0 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

For general motor starting (AC-3), the part is typically applied up to its 7.5 kW (AC-2) or 11 kW (690 V) capability, but the datasheet does not list a separate AC-3 figure; the AC-2 and AC-4 values bound the envelope. The operating voltage range is 0.8 to 1.1 times the rated control supply voltage at 50 Hz, so a 230 V coil holds in from about 184 V to 253 V.

For type 1 coordination (contactor may need replacement after a fault), use a 63 A gL/gG fuse. The rated frequency is 50 Hz.

Frequently asked questions

What wire sizes does the screw terminal accept?

Solid conductors: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², max 2x 0.75 to 4 mm². Stranded: 2x 1 to 2.5 mm², 2x 2.5 to 6 mm², max 2x 10 mm². AWG: 2x 16 to 12, 2x 14 to 10, 1x 8.

Can this contactor be mounted side-by-side with other devices?

Yes, side-by-side mounting is allowed. Maintain 6 mm clearance to adjacent devices on the side.