Siemens 3RT1026-1AF00-1AA0 SIRIUS Power Contactor, 11 kW at

MPN3RT1026-1AF00-1AA0

Siemens SIRIUS 3RT1026-1AF00-1AA0 power contactor, S0 frame, 3-pole NO, 11 kW at 690 V AC-3, screw terminals, 45 mm wide, current lifecycle.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1026-1AF00-1AA0 — Identification
ParameterValue
Contactor frame sizeS0
3RT1026-1AF00-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V11 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1026-1AF00-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1026-1AF00-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1026-1AF00-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 100 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1026-1AF00-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Side-by-side mountingYes
3RT1026-1AF00-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1026-1AF00-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1026-1AF00-1AA0 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

It carries 11 kW at 500 V and the same 11 kW at 690 V under AC-3 duty, which means it handles standard squirrel-cage motors up to those ratings without derating for the higher voltage. For AC-2 duty (slip-ring motors, resistive loads) it still delivers 11 kW at 400 V.

Main circuit terminals are screw-type, accepting solid conductors from 2x 0.5 mm² up to 2x 4 mm², and stranded conductors from 2x 1 mm² up to 2x 10 mm² (or 1x 8 AWG). That covers most panel wiring from control circuits up to motor feeders. The IP20 front protection means accidental finger contact is blocked, while the terminals themselves are IP00 — standard for enclosed panels where the gland plate or cabinet door provides the environmental seal.

Auxiliary and control ratings

The contactor carries 3 normally-open main contacts (no NC main poles). For auxiliary switching, the control circuit ratings cover a range: 10 A at 24 V DC, 6 A at 230 V AC, 3 A at 400 V AC, and down to 0.3 A at 220 V DC. The 50 Hz rated control supply voltage is 110 V (with a tolerance of 0.8 to 1.1 times nominal). If you're using this in a 24 V DC control scheme, the 10 A auxiliary rating gives headroom for pilot lights, PLC inputs, or interlocking relays.

Frequently asked questions

What is the closest functional alternative to this contactor?

The 3RT1017-1AP01 is a smaller S0 frame contactor with lower power ratings. It will not drop into a panel specified for the 3RT1026-1AF00-1AA0 without checking the motor load — the 3RT1017 is rated for lower kW at the same voltages. If your BOM calls for 11 kW at 690 V, the 3RT1026 is the correct frame size.

What are the key dimensions for panel layout?

Width is 45 mm, height 85 mm, depth 91 mm. It mounts on 35 mm DIN rail and allows side-by-side mounting with no gap.

What conductor sizes does the screw terminal accept?

Solid conductors: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², max 2x 0.75 to 4 mm². Stranded: 2x 1 to 2.5 mm², 2x 2.5 to 6 mm², max 2x 10 mm². AWG equivalents: 2x 16-12, 2x 14-10, 1x 8.

What short-circuit coordination fuses are required?

Type 2 coordination requires a gL/gG 35 A fuse upstream. Type 1 coordination allows a gL/gG 100 A fuse.

MPN
3RT1026-1AF00-1AA0