Siemens 3RT1026-1AP00-ZW98 — Contactors

Siemens 3RT1026-1AP00-ZW98 SIRIUS Power Contactor, S0, 3NO,

MPN3RT1026-1AP00-ZW98

Siemens SIRIUS power contactor, 3RT1026-1AP00-ZW98, size S0, 3 NO main contacts, screw-type terminals, 11 kW at 400 V AC-2, 15.5 A at 400 V AC-4, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1026-1AP00-ZW98 — Identification
ParameterValue
Contactor frame sizeS0
3RT1026-1AP00-ZW98 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V11 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1026-1AP00-ZW98 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1026-1AP00-ZW98 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1026-1AP00-ZW98 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 100 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1026-1AP00-ZW98 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (1 ... 2,5 mm²), 2x (2,5 ... 6 mm²), max. 2x 10 mm²
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1026-1AP00-ZW98 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1026-1AP00-ZW98 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1026-1AP00-ZW98 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth91 mm

Product details

It carries three normally-open main contacts rated for 11 kW at 400 V in AC-2 duty (slip-ring motor starting) and 15.5 A at 400 V in AC-4 duty (plugging and inching).

The 45 mm width and 85 mm height keep it compact for dense rail layouts. Side-by-side mounting is supported, which means no mandatory spacing between contactors on the same rail.

Termination and wiring

Main and auxiliary circuits use screw-type terminals. The main contacts accept solid or stranded wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²). For AWG, that's 2x (16 to 12), 2x (14 to 10), or 1x 8. Auxiliary terminals take 2x (20 to 16), 2x (18 to 14), or 1x 12 AWG. These ranges cover common panel wire sizes without needing terminal reducers.

Protection and coordination

For type 1 coordination (contactor may need replacement after fault), the fuse can be gL/gG 100 A.

The front panel is IP20 (finger-safe), while the terminals are IP00 (no finger protection at the wiring point — panel builders should account for this in enclosure design). The part complies with RoHS substance prohibitance dated July 1, 2006, covering the standard EU RoHS scope.

Frequently asked questions

What are the key motor ratings for this contactor?

It is rated 11 kW at 400 V AC-2, 15.5 A at 400 V AC-4, and also 11 kW at both 500 V and 690 V. These cover slip-ring motor starting, plugging/inching, and higher-voltage motor circuits.

What upstream fuse protection is required?

For type 2 coordination (no damage to the contactor), use a gL/gG 35 A fuse. For type 1 coordination (contactor may need replacement after a fault), a gL/gG 100 A fuse is acceptable.

What is the operating temperature range?

The contactor operates from -25 °C to +60 °C during operation, suitable for most indoor industrial environments.

What wire sizes does the screw terminal accept?

Main contacts accept 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), or max 2x (0.75 to 4 mm²) solid or stranded. AWG equivalents are 2x (16 to 12), 2x (14 to 10), or 1x 8.

MPN
3RT1026-1AP00-ZW98