Siemens 3RT1026-1KB40-1AA0 — Contactors

Siemens 3RT1026-1KB40-1AA0 SIRIUS Power Contactor, 24 VDC, 1

MPN3RT1026-1KB40-1AA0

Siemens SIRIUS 3RT1026-1KB40-1AA0 power contactor, size S0, 24 VDC coil, 11 kW rated power at 400 V AC-3, screw-type terminals, integrated varistor.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1026-1KB40-1AA0 — Identification
ParameterValue
Contactor frame sizeS0
3RT1026-1KB40-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V11 kW
Rated value @ 500 V11 kW
Rated value @ 690 V11 kW
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1026-1KB40-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1026-1KB40-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1026-1KB40-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 100 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1026-1KB40-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
3RT1026-1KB40-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
3RT1026-1KB40-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Installation altitude, max.2 000 m
3RT1026-1KB40-1AA0 — Mechanical
ParameterValue
Width45 mm
Height88 mm
Depth101 mm

Product details

It carries an 11 kW motor rating at 400 V under AC-3 duty (the standard for squirrel-cage motors starting and stopping under load), and the same 11 kW at 400 V under AC-2 duty (slip-ring motors or resistive-inductive loads). The 24 VDC coil draws 4.2 W to close and holds at 4.2 W — a constant-hold design that simplifies the control transformer sizing because there's no inrush-to-hold drop.

At 45 mm wide, it takes up one standard module slot on the rail. Depth is 101 mm — that's the dimension you need to clear the enclosure door or back panel. Height is 88 mm. Main circuit terminals are screw-type, accepting solid conductors from 2x (0.5 to 1.5 mm²) up to a maximum of 2x (0.75 to 4 mm²), or stranded 2x (1 to 2.5 mm²) up to 2x 10 mm² max. Auxiliary and control circuit terminals are also screw-type. Strip and torque per standard panel practice — these aren't spring-cage, so a screwdriver and a torque driver are part of the install.

That's a practical difference: if you're designing for minimal downtime after a short circuit, the 35 A fuse limit governs your branch protection choice. The contactor includes an integrated varistor surge suppressor across the coil, so you don't need to add an external RC snubber or diode for DC coil suppression. Pollution degree 3 (conductive pollution) means it's rated for the typical industrial control panel environment without conformal coating.

Thermal and life considerations

Frequently asked questions

What is the depth of this contactor?

The depth is 101 mm. This is the dimension from the DIN rail mounting surface to the front of the contactor, important for enclosure depth clearance.

What conductor sizes fit the main terminals?

The main screw terminals accept solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²). For stranded: 2x (1 to 2.5 mm²), 2x (2.5 to 6 mm²), and max 2x 10 mm². AWG equivalents are 2x (16 to 12), 2x (14 to 10), and 1x 8.

MPN
3RT1026-1KB40-1AA0