Siemens 3RT1026-3AU60 SIRIUS Power Contactor, S0, 3NO, 11 kW

MPN3RT1026-3AU60

Siemens SIRIUS 3RT1026-3AU60 power contactor, size S0, 3-pole normally open main contacts, screw-type terminals, 11 kW at 400 V AC-2, 15.5 A AC-4.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1026-3AU60 — Identification
ParameterValue
Contactor frame sizeS0
3RT1026-3AU60 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V11 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1026-3AU60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1026-3AU60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1026-3AU60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 100 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1026-3AU60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1026-3AU60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1026-3AU60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1026-3AU60 — Mechanical
ParameterValue
Width45 mm
Height85 mm
Depth90 mm

Product details

Rated at 11 kW at 400 V in AC-2 duty (slip-ring motors, moderate overloads) and 15.5 A in AC-4 duty (plugging, inching, reversing). These are the numbers that govern real motor switching — not a generic thermal current. For short-circuit protection, the contactor coordinates with a 35 A gL/gG fuse under Type 2 coordination (limited damage to the contactor) or a 100 A gL/gG fuse under Type 1 coordination (contactor may need replacement after a fault). The auxiliary contact block (not included) can be mounted on the front or side; side-by-side mounting is permitted with 6 mm spacing to adjacent devices.

Frequently asked questions

What are the main contact ratings for motor loads?

It is rated 11 kW at 400 V AC-2 and 15.5 A at 400 V AC-4. These duty-specific ratings define its capability for different motor starting regimes.

What is the physical size and mounting?

The contactor is size S0, 45 mm wide, 85 mm high, 90 mm deep. It snaps onto a 35 mm DIN rail per DIN EN 50022 or can be screw-mounted.

What terminal type does it use?

Screw-type terminals on the main current circuit, accepting 2x (0.25...2.5 mm²) solid, 2x (1...2.5 mm²) stranded, or up to 2x 10 mm² / 1x 8 AWG.

MPN
3RT1026-3AU60