Siemens 3RT1026-3EG28-0MA3 — Contactors

Siemens 3RT1026-3EG28-0MA3 SIRIUS Power Contactor, S0, 11 kW

MPN3RT1026-3EG28-0MA3

Siemens SIRIUS 3RT1026-3EG28-0MA3 power contactor, S0 frame size, 11 kW AC-2 at 400 V, 15.5 A AC-4, screw-type terminals, built-in RC surge suppressor.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1026-3EG28-0MA3 — Identification
ParameterValue
Contactor frame sizeS0
3RT1026-3EG28-0MA3 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V11 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1026-3EG28-0MA3 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1026-3EG28-0MA3 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1026-3EG28-0MA3 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 100 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1026-3EG28-0MA3 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1026-3EG28-0MA3 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1026-3EG28-0MA3 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1026-3EG28-0MA3 — Mechanical
ParameterValue
Width45 mm
Height88 mm
Depth140 mm

Product details

It carries an AC-2 rating of 11 kW at 400 V — that's the slip-ring motor duty where starting current and switching frequency are moderate, so it fits applications like conveyors, pumps, and compressors that don't need heavy inching. The built-in RC surge suppressor means you don't need to order a separate varistor or snubber for coil suppression on standard AC control voltages.

Ratings that matter for fit

The AC-4 rating (15.5 A at 400 V) is the one to check if your application does frequent reversing or inching — that's where the contactor sees arcing on every break, so the current limit is lower than the AC-3 or AC-2 numbers. Short-circuit protection requires a gL/gG fuse rated at 35 A for type 2 coordination.

Frequently asked questions

What are the key motor ratings for this contactor?

AC-2 duty at 400 V is 11 kW; AC-4 duty at 400 V is 15.5 A. The AC-2 rating governs normal start-run motor switching; the AC-4 rating governs reversing or inching cycles.

What short-circuit protection does it require?

For type 2 coordination, a gL/gG fuse rated at 35 A is specified.

Does it include a surge suppressor?

Yes, it comes with a built-in RC surge suppressor across the coil.

MPN
3RT1026-3EG28-0MA3