Skip to main content
Siemens 3RT1026-8BB45-1PB2 — Contactors

Siemens 3RT1026-8BB45-1PB2 SIRIUS Power Contactor, 24 VDC, S

MPN3RT1026-8BB45-1PB2

Siemens SIRIUS power contactor, 24 VDC coil, S0 size, screw terminals, 11 kW at 400 V AC-3, 55 x 85 x 101 mm.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1026-8BB45-1PB2 — Identification
ParameterValue
Contactor frame sizeS0
3RT1026-8BB45-1PB2 — Ratings & Performance
ParameterValue
Rated operational current, AC-4 @ 400 V15.5 A
Rated value @ 400 V3 A
Rated value @ 500 V11 kW
Rated value @ 690 V11 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1026-8BB45-1PB2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1026-8BB45-1PB2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1026-8BB45-1PB2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 100 A
Short-circuit coordination type 2, fusefuse gL/gG: 35 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1026-8BB45-1PB2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Side-by-side mountingYes
3RT1026-8BB45-1PB2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1026-8BB45-1PB2 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
3RT1026-8BB45-1PB2 — Mechanical
ParameterValue
Width55 mm
Height85 mm
Depth101 mm

Product details

The S0 frame keeps the footprint compact at 55 mm wide, 85 mm tall, and 101 mm deep — a direct fit into most distribution or motor-control enclosures without extra spacing.

The 11 kW rating at 400 V AC-3 is the headline motor-switching figure — it tells you the contactor can start and stop a 400 V three-phase induction motor up to that shaft power. The AC-4 rating of 15.5 A at 400 V is the one to watch for plugging or jogging duty; if your application cycles the contactor under load, that 15.5 A limit governs, not the AC-3 kW number. The coil draws 5.4 W both on closing and holding, which is a constant DC load on the 24 V supply — no surge beyond the pick-up power. The front face carries IP20 finger protection; the terminals themselves are IP00, meaning the wiring compartment expects enclosure protection from the panel.

If you are evaluating a panel originally built around the smaller 3RT1015-1BB42, the S0 frame of this contactor is physically larger — 55 mm wide versus the S00 frame's 45 mm — so verify DIN-rail space and terminal clearance before assuming a drop-in swap. The screw terminals accept up to 2x 10 mm² or 1x 8 AWG for the main circuit, which covers most motor feeds up to the 11 kW rating.

Frequently asked questions

What are the key ratings for this contactor?

The headline ratings are 11 kW at 400 V AC-3 for motor starting, 15.5 A at 400 V AC-4 for reversing duty, and a 24 VDC coil drawing 5.4 W. Operating temperature range is -25 to +60 °C.

Will this contactor fit a panel designed for the 3RT1015-1BB42?

Not without checking space. The 3RT1026-8BB45-1PB2 uses the S0 frame (55 mm wide), while the 3RT1015-1BB42 is an S00 frame (45 mm wide). The extra 10 mm width and different terminal layout mean you should verify DIN-rail clearance and wiring access before assuming a direct swap.

What wire sizes does the main circuit accept?

The screw terminals accept 2x (1 to 2.5 mm²), 2x (2.5 to 6 mm²), or max. 2x 10 mm² solid/stranded, and 2x (16 to 12 AWG), 2x (14 to 10 AWG), or 1x 8 AWG.

MPN