Siemens 3RT1034-1AB04 — Contactors

Siemens 3RT1034-1AB04 SIRIUS Power Contactor, 15 kW AC-2 at

MPN3RT1034-1AB04

Siemens SIRIUS 3RT1034-1AB04 power contactor, S2 frame, screw-type terminals, 15 kW AC-2 at 400 V, 55 mm width, snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AB04 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AB04 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AB04 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1034-1AB04 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AB04 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AB04 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AB04 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AB04 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1034-1AB04 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Its AC-2 rating at 400 V delivers 15 kW, which covers squirrel-cage motors on slip-ring starting or wound-rotor applications where the duty cycle includes moderate inrush.

For resistive loads (AC-1), the maximum operating rate is 1 200 cycles per hour; for AC-4 plugging duty, that drops to 250 cycles per hour — the thermal capacity of the S2 frame governs the duty cycle, not just the steady-state current. Coil draw at 24 V rated value is 10 A, at 60 V it is 2 A, and at 230 V it is 6 A — these are the pick-up and hold currents the PLC output or control transformer must supply. Front protection is IP20 (finger-safe), while the terminal area is IP00 — the panel builder must ensure the gland plate and enclosure maintain the overall IP rating.

No separate REACH or UL declaration is in this evidence, but as a Siemens SIRIUS catalog part it carries CE marking under the Low Voltage Directive by design.

Main current circuit terminals are screw-type, accepting solid conductors from 2x (0.5 to 1.5 mm²) up to 2x (0.75 to 4 mm²), and stranded from 2x (0.75 to 25 mm²). The minimum permissible cross-section at 40 °C is 16 mm² for the main circuit — this is the thermal derating floor, not a recommendation for smaller control wiring. Auxiliary and coil terminals use the same screw clamp range. Height is 112 mm. When planning panel layout, allow clearance above and below for arc venting and screwdriver access to the terminals.

Frequently asked questions

What is the closest functional second-source for this contactor?

The 3RT1034-1AN60-1AA0 is a peer variant with the same S2 frame and AC-2/AC-4 ratings but includes an integrated auxiliary contact block and a different coil voltage. It will drop into the same DIN-rail footprint and terminal pattern, so a panel designed around the 3RT1034-1AB04 can accept the -1AN60-1AA0 without rewiring the main power circuit — only the coil supply needs verification.

What compliance documentation does this contactor carry?

RoHS compliance is confirmed with a substance prohibition date of 05/01/2012. As a Siemens SIRIUS catalog part, it carries CE marking under the Low Voltage Directive; UL and CSA listings are standard for this family but not explicitly confirmed in this evidence.

What are the key ratings for BOM verification?

AC-2 motor power at 400 V is 15 kW; AC-4 breaking current at 400 V is 29 A. Coil draw at 24 V is 10 A. The contactor is 55 mm wide, 112 mm high, 164 mm deep, and mounts on 35 mm DIN rail.