Siemens 3RT1034-1AG20 — Contactors

Siemens 3RT1034-1AG20 SIRIUS Power Contactor, 110 VAC Coil,

MPN3RT1034-1AG20

Siemens SIRIUS power contactor, 3RT1034-1AG20, size S2, 110 V 50/60 Hz coil, 18.5 kW at 500 V AC-3, screw terminals, snap-on 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AG20 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AG20 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AG20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1034-1AG20 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AG20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AG20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AG20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AG20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AG20 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1034-1AG20 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

SIRIUS S2 Power Contactor, 110 VAC Coil

The Siemens SIRIUS 3RT1034-1AG20 is a size S2 power contactor with a 110 V 50/60 Hz coil, rated for motor switching at 18.5 kW at 500 V in AC-3 duty and 10 kW at 690 V.

The 18.5 kW at 500 V AC-3 rating is the motor-switching figure that governs real-world sizing for standard squirrel-cage induction motors. The 10 kW at 690 V extends the contactor into higher-voltage, lower-current applications. AC-2 at 400 V is rated at 15 kW, covering slip-ring motor duties. The 110 V 50/60 Hz coil has an operating range of 0.8 to 1.1 at 50 Hz and 0.85 to 1.1 at 60 Hz, so the coil holds in reliably even with a sagging control supply.

Switching Rates and Mechanical Life

Maximum switching rates are 1200 cycles/hour for AC-1 resistive loads, 1000 for AC-3 motor starts, and 250 for AC-4 plugging/inching.

Main circuit terminals accept stranded wire up to 2x 25 mm² or solid up to 2x 4 mm². Pollution degree 3 means it handles conductive pollution in industrial atmospheres.

Frequently asked questions

What are the key motor ratings for this contactor?

The contactor is rated 18.5 kW at 500 V AC-3, 10 kW at 690 V AC-3, and 15 kW at 400 V AC-2. These are the figures to use for motor sizing.

What coil voltage does this contactor use?

The coil is rated 110 V at both 50 Hz and 60 Hz, with an operating range of 0.8 to 1.1 at 50 Hz and 0.85 to 1.1 at 60 Hz.

What wire sizes does the main circuit accept?

Screw terminals accept stranded wire 2x (0.75 to 25 mm²) and solid wire 2x (0.5 to 4 mm²).

Can the 3RT1034-1AG20 be mounted side-by-side with other contactors?

Yes, side-by-side mounting is permitted without derating, allowing dense panel layouts.

MPN
3RT1034-1AG20