Siemens 3RT1034-1AG60 SIRIUS Power Contactor, S2 Size, 18.5

MPN3RT1034-1AG60

Siemens SIRIUS power contactor, order code 3RT1034-1AG60, S2 size, 18.5 kW at 500 V AC-3, screw terminals, 55 mm width, snap-on DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AG60 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AG60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AG60 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz100 V
3RT1034-1AG60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AG60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AG60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AG60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AG60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AG60 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1034-1AG60 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

The S2 frame size (55 mm wide, 112 mm height, 115 mm depth) fits standard panel layouts; side-by-side mounting is permitted without derating for thermal stacking within the rated operating range of -25 to +60 °C.

Motor Duty & Ratings

Rated for AC-3 motor switching at 18.5 kW at 500 V (50/60 Hz), with a maximum electrical endurance of 1 000 operations per hour under AC-3 duty. For heavier AC-4 inching or plugging, the rate drops to 250 operations per hour — plan the application cycle accordingly. Coil draw at 24 V rated value is 10 A, and the contactor handles a pollution degree of 3 (conductive pollution typical in industrial enclosures).

Termination & Wiring

Screw-type terminals accept solid conductors up to 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²), and stranded up to 2x (0.75... 25 mm²). The wide clamping range covers standard control and power wiring without needing adapter lugs.

Frequently asked questions

What are the key mounting dimensions?

Width 55 mm, height 112 mm, depth 115 mm. Mounts via screw and snap-on onto 35 mm DIN rail per EN 50022. Side-by-side mounting is permitted.

What conductor sizes does the screw terminal accept?

Solid: 2x (0.5... 1.5 mm²) or 2x (0.75... 2.5 mm²), max 2x (0.75... 4 mm²). Stranded: 2x (0.75... 25 mm²).

What is the motor power rating at 500 V?

18.5 kW at 500 V AC-3 duty (50/60 Hz). Also rated 15 kW at 400 V AC-2 and 10 kW at 690 V.

MPN
3RT1034-1AG60