Skip to main content
Siemens 3RT1034-1AL24 — Contactors

Siemens 3RT1034-1AL24 SIRIUS Power Contactor

MPN3RT1034-1AL24

Siemens SIRIUS S2 power contactor, 3RT1034-1AL24, 55 mm wide, screw terminals, 18.5 kW at 500V AC-3, 10 kW at 690V AC-3.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AL24 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AL24 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AL24 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1034-1AL24 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AL24 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AL24 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AL24 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AL24 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AL24 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1034-1AL24 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

The Siemens 3RT1034-1AL24 is a SIRIUS S2-frame power contactor rated for motor switching up to 18.5 kW at 500 V AC-3 duty and 10 kW at 690 V AC-3, making it a fit for 400 V to 690 V three-phase motor loads in industrial control panels. Its AC-2 rating of 15 kW at 400 V covers slip-ring motor or high-inertia starts where the inrush extends beyond the AC-3 window.

The headline AC-3 rating of 18.5 kW at 500 V tells you the contactor can handle a standard three-phase squirrel-cage induction motor of that power through normal starting and running — that's the common duty for pumps, fans, and conveyors. The 10 kW at 690 V rating extends its reach into higher-voltage installations common in mining or marine applications. The AC-4 rating at 400 V (not fully listed in the excerpt) would govern plugging or inching duty; the 250 cycles/hour maximum at AC-4 sets the thermal limit for reversing or jogging applications. Side-by-side mounting is permitted, which saves rail space in multi-contactor assemblies like star-delta starters. Operating temperature spans -25 °C to +60 °C, with storage from -55 °C to +80 °C.

At 55 mm wide and 112 mm tall, the S2 frame fits standard 35 mm DIN rail with snap-on mounting. Depth of 164 mm accounts for the screw terminals and arc chamber — verify clearance to the gland plate or enclosure door. The screw terminals accept solid conductors up to 2x 4 mm² and stranded up to 2x 25 mm², covering most motor circuit wiring up to the rated current. Coil operating range is 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz. Arcing time of 10 to 15 ms and AC operating time of 7 to 20 ms are typical for this contactor class.

Frequently asked questions

What is the replacement for 3RT1034-1AL24?

The part is phased out, so buyers must know the exact successor to avoid production downtime.

Is 3RT1034-1AL24 obsolete?

Determines whether to continue sourcing or switch to the alternative model.

What are the specifications of 3RT1034-1AL24?

Engineers need to verify fit, ratings, and contact configuration for design validation.

Where can I buy 3RT1034-1AL24?

Sourcing buyers need to locate stock quickly to fill BOM lines.

What is the difference between 3RT1034-1AL24 and 3RT2027-1AL24?

To evaluate if the successor is a drop-in replacement or requires design changes.

How much does 3RT1034-1AL24 cost?

Price transparency is critical for budget planning and supplier selection.

MPN
3RT1034-1AL24