Specifications

3RT1034-1AR60-ZX95 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AR60-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AR60-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1034-1AR60-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AR60-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AR60-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AR60-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AR60-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AR60-ZX95 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1034-1AR60-ZX95 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It is rated for 15 kW at 400 V in AC-2 duty, which covers slip-ring motor starting and plugging applications, and 18.5 kW at 500 V in AC-3 for standard squirrel-cage motors. The coil operates on 50 Hz at 400 V or 60 Hz at 400 to 440 V, with an operating range of 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz.

Dimensions: 55 mm wide, 112 mm high, 115 mm deep. Side-by-side mounting is permitted, which saves panel width when grouping multiple contactors. Main circuit connections use screw-type terminals; wire ranges accept solid conductors from 2x 0.5 to 4 mm² and stranded from 2x 0.75 to 25 mm².

Environmental and protection ratings

Front face carries IP20 finger protection; terminals are IP00, so the contactor needs to be housed in a panel or enclosure with a higher overall IP rating.

Switching performance and auxiliary ratings

Rated for 1,200 operations per hour in AC-1, 750 in AC-2, 1,000 in AC-3, and 250 in AC-4. Auxiliary contacts are rated for 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V.

Frequently asked questions

What is the closest functional alternative to 3RT1034-1AR60-ZX95?

The peer 3RT1034-1AN60-1AA0 is a close functional match within the same SIRIUS S2 size, but the -ZX95 variant carries a specific coil voltage (400 V at 50 Hz, 400-440 V at 60 Hz) and auxiliary contact configuration. Verify coil compatibility before substituting — the -1AN60-1AA0 uses a different coil voltage range.

What are the key dimensions of this contactor?

Width is 55 mm, height is 112 mm, and depth is 115 mm. It mounts on 35 mm DIN rail per EN 50022.

What wire sizes does the main circuit accept?

Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (0.75 to 25 mm²). Solid or stranded: 2x (0.75 to 16 mm²).

Will 3RT1034-1AR60-ZX95 drop into a panel designed for 3RT1034-1AN60-1AA0 without rewiring?

Mechanically yes — same S2 size, same DIN rail footprint, same screw terminal locations. Electrically, verify the coil voltage: the -ZX95 uses 400 V at 50 Hz / 400-440 V at 60 Hz, while the -1AN60-1AA0 uses a different coil. If coil voltages match, no rewiring is needed for the power circuit.

MPN
3RT1034-1AR60-ZX95