Siemens 3RT1034-1AR64 SIRIUS Power Contactor, S2 Size, 400V

MPN3RT1034-1AR64

Siemens SIRIUS power contactor, 3RT1034-1AR64, size S2, 400 V at 50 Hz rated, screw-type terminals, screw and snap-on mounting onto 35 mm DIN rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AR64 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AR64 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AR64 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1034-1AR64 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AR64 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AR64 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AR64 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AR64 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AR64 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1034-1AR64 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Rated at 400 V at 50 Hz, it delivers 15 kW in AC-2 duty and 18.5 kW at 500 V, making it suitable for squirrel-cage motors on conveyors, pumps, and fans where the load profile matches AC-2 or AC-3 switching.

The AC-2 rating of 15 kW at 400 V covers slip-ring motor starting where the current stays closer to running levels. Switching frequency limits are 1 000 operations per hour in AC-3 and 750 in AC-2, so it's not meant for high-cycle applications like rapid reversing or jogging — those would need AC-4 rated gear at 250 ops/h. The 10 A at 24 V means it can drive multiple small loads without an interposing relay.

Environmental and Mounting Considerations

IP20 on the front, IP00 at the terminals — the terminal area is open, so it requires enclosure protection against accidental contact. Side-by-side mounting is allowed, which saves rail space in dense panels. Dimensions are 112 mm high, 55 mm wide, 164 mm deep — the S2 frame size fits standard 55 mm-wide contactor slots in most pre-drilled panel layouts.

Frequently asked questions

What wire sizes does the screw terminal accept?

Solid wire: 2x 0.5 to 1.5 mm² and 2x 0.75 to 2.5 mm², max 2x 0.75 to 4 mm². Stranded: 2x 0.75 to 25 mm². Solid or stranded: 2x 0.75 to 16 mm².

Can it be mounted side by side with other contactors?

Yes, side-by-side mounting is permitted, which saves DIN rail space in dense panels.