Siemens 3RT1034-1AU00 — Contactors

Siemens 3RT1034-1AU00 SIRIUS Power Contactor, S2 Size, 18.5

MPN3RT1034-1AU00

Siemens SIRIUS power contactor, S2 size, 3RT1034-1AU00, 18.5 kW at 400 V AC-3, screw-type terminals, 55 mm wide, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AU00 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AU00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AU00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz240 V
3RT1034-1AU00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AU00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AU00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AU00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AU00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AU00 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1034-1AU00 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It's rated for 18.5 kW at 400 V in AC-3 duty (squirrel-cage motors) and 15 kW at 400 V in AC-2 duty (slip-ring motors), so the AC-3 figure is the one you size for a standard induction motor on a conveyor or pump.

At 55 mm wide and 112 mm tall, it fits a standard 6-module wide slot in a panel.

Main circuit terminals accept solid wire from 0.5 mm² up to 4 mm² (two conductors per clamp) and stranded from 0.75 mm² up to 25 mm². That 25 mm² stranded capacity is generous for an S2 contactor — it means you can land a 6 AWG feed without a ferrule if the lug is rated for it. The control circuit (coil) terminals are separate; the evidence doesn't specify their wire range, but standard practice on this series is 0.5–2.5 mm². Strip length for all terminals is typically 10–12 mm; use ferrules on stranded wire below 1.5 mm² to avoid whiskers under the screw.

Pollution degree 3. RoHS compliance with substance prohibition date of 05/01/2012.

Frequently asked questions

Will 3RT1034-1AU00 drop into a panel built around 3RT1034-1AN60-1AA0 without rewiring?

Both are S2 frame contactors with screw-type terminals and the same DIN-rail footprint, so the physical fit and main circuit wiring are identical. The difference is in the coil voltage or auxiliary contact configuration — check those against your schematic before ordering.

What is the depth of 3RT1034-1AU00?

The depth is 115 mm, which is the dimension from the DIN rail clip to the front face of the contactor.

MPN
3RT1034-1AU00