Siemens 3RT1034-1AV00 — Contactors

Siemens 3RT1034-1AV00 SIRIUS Power Contactor, S2, 18.5 kW at

MPN3RT1034-1AV00

Siemens SIRIUS 3RT1034-1AV00 power contactor, size S2, screw-type terminals, 18.5 kW at 500 V AC-3, 55 mm width, IP20 front.

$133.35Ref. price · indicative, final on quote
Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1AV00 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1AV00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1AV00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1034-1AV00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1AV00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1AV00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1AV00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1AV00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1AV00 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1034-1AV00 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

For heavy-duty jogging or inching (AC-4), it is rated 29 A at 400 V, so it handles the high electrical wear of plugging and reversing without derating prematurely.

Footprint is 55 mm wide, 112 mm high, 115 mm deep. Side-by-side mounting allowed. Operating range -25 to +60 °C.

Main current circuit terminals are screw-type, accepting solid conductors from 2x (0.5... 1.5 mm²) up to max 2x (0.75... 4 mm²), and stranded conductors from 2x (0.75... 25 mm²). The auxiliary and control circuit terminals accept solid or stranded 2x (0.75... 16 mm²). For a wireman landing motor leads, the large stranded range covers common 4 mm² to 16 mm² motor cables without needing pin terminals — though ferrules are recommended for fine-stranded wire. The terminal protection rating is IP00 (open), while the front enclosure carries IP20, so the contactor is suitable for enclosed panels where the door provides the overall IP rating.

Operational frequency reaches 1,200 switching cycles per hour at AC-1 (resistive), 1,000 at AC-3 (motor running), and 250 at AC-4 (inching/jogging). The coil operates on 50 Hz with a voltage tolerance of 0.8 to 1.1 times the rated value. For the control engineer: the 24 V DC rated current is 10 A, and the 230 V rated current is 6 A, so the auxiliary contacts can drive small contactors or indicator loads directly.

MPN
3RT1034-1AV00