Skip to main content
Siemens 3RT1034-1CP04-0KV0 — Contactors

Siemens 3RT1034-1CP04-0KV0 SIRIUS Power Contactor, S2 Size,

MPN3RT1034-1CP04-0KV0

Siemens SIRIUS 3RT1034-1CP04-0KV0, S2 size power contactor, screw-type terminals, 15 kW at AC-2 400 V, 29 A at AC-4 400 V, 55 mm wide, 112 mm high, 164 mm deep.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-1CP04-0KV0 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-1CP04-0KV0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-1CP04-0KV0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1034-1CP04-0KV0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-1CP04-0KV0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-1CP04-0KV0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-1CP04-0KV0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-1CP04-0KV0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-1CP04-0KV0 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1034-1CP04-0KV0 — Specifications
ParameterValue
At AC15g / 5 ms, 8g / 10 ms

Product details

At AC-2 duty (starting and stopping slip-ring motors), the contactor is rated 15 kW at 400 V — that's the figure that governs the motor load it can handle in that application. For AC-4 duty (plugging, inching, reversing), it's rated 29 A at 400 V, which is the higher thermal stress from frequent switching. The auxiliary contact block handles 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — these are the limits for the control circuit, not the main power path.

The contactor is 55 mm wide, 112 mm high, and 164 mm deep. It accepts screw-type terminals for the main circuit: solid or stranded wire 2x (0.75...16 mm²), and stranded alone up to 2x (0.75...25 mm²).

Frequently asked questions

What are the key motor ratings for this contactor?

At AC-2 duty, it is rated 15 kW at 400 V. At AC-4 duty, it is rated 29 A at 400 V. These are the figures that determine the motor load it can handle in those specific applications.

What compliance documentation does this part have?

The part has a substance prohibition date of 05/01/2012, indicating RoHS compliance. It is rated for pollution degree 3, suitable for industrial environments.

MPN
3RT1034-1CP04-0KV0