Skip to main content
Siemens 3RT1034-3AF04 — Contactors

Siemens 3RT1034-3AF04 SIRIUS Power Contactor, Size S2, 15kW

MPN3RT1034-3AF04

Siemens SIRIUS power contactor, 3RT1034-3AF04, size S2, screw-type terminals, 15 kW at 400 V AC-2, 29 A at 400 V AC-4, 55 mm width, DIN EN 50022 rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-3AF04 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-3AF04 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-3AF04 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1034-3AF04 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-3AF04 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-3AF04 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-3AF04 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-3AF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-3AF04 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1034-3AF04 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Rated for AC-2 duty at 15 kW at 400 V, this contactor handles slip-ring motor starting and reversing. For inching and plugging duty (AC-4), it carries 29 A at 400 V, which is the rating that governs real-world life in demanding applications — not the higher AC-3 number. The main power circuit uses screw-type terminals, accepting 2x (0.75... 25 mm²) stranded or 2x (0.25... 2.5 mm²) solid conductors. The minimum permissible cross-section at 40 °C is 16 mm², which is the wire size needed to carry the rated current without derating. Coil pickup currents are specified across the voltage range: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V. The coil operates reliably between 0.8 and 1.1 times the rated voltage at 50 Hz.

Switching frequencies are rated per duty class: 1,200 operations per hour for AC-1 resistive loads, 750 for AC-2, 1,000 for AC-3, and 250 for AC-4.

RoHS compliance is documented with a substance prohibition date of May 1, 2012, indicating the part meets the EU RoHS directive for hazardous substance restrictions. REACH and other regulatory documentation is available from the manufacturer.

Frequently asked questions

What are the key motor ratings for this contactor?

The 3RT1034-3AF04 is rated 15 kW at 400 V for AC-2 duty (slip-ring motors) and 29 A at 400 V for AC-4 duty (inching/plugging). At 500 V it handles 18.5 kW, and at 690 V it handles 10 kW.

What wire sizes does the screw terminal accept?

The main circuit terminals accept 2x (0.75... 25 mm²) stranded or 2x (0.25... 2.5 mm²) solid conductors. The minimum cross-section at 40 °C is 16 mm².

What is the physical size and mounting method?

The contactor is 55 mm wide, 112 mm high, and 164 mm deep. It mounts on a 35 mm DIN rail per DIN EN 50022 using screw fixing or snap-on clip, and allows side-by-side mounting.

What compliance documentation is available?

RoHS compliance is documented with a substance prohibition date of May 1, 2012. The part carries IP20 front protection and IP00 terminal protection, and is rated for pollution degree 3 environments.

MPN
3RT1034-3AF04