Siemens 3RT1034-3BW40 SIRIUS Power Contactor, Size S2, 18.5

MPN3RT1034-3BW40

Siemens SIRIUS power contactor, Size S2, 3RT1034-3BW40, 18.5 kW at 500 V AC-3, 29 A AC-4 at 400 V, screw terminals, DIN rail mount, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1034-3BW40 — Identification
ParameterValue
Contactor frame sizeS2
3RT1034-3BW40 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V29 A
Rated value @ 400 V3 A
Rated value @ 500 V18.5 kW
Rated value @ 690 V10 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1034-3BW40 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1034-3BW40 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1034-3BW40 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1034-3BW40 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1034-3BW40 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1034-3BW40 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1034-3BW40 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth130 mm

Product details

Its AC-3 rating of 18.5 kW at 500 V means it handles standard squirrel-cage motors up to that power — the typical duty for conveyors, pumps, and fans. AC-2 at 400 V is rated 15 kW, covering slip-ring motor starting. Main circuit connections use screw-type terminals, accepting solid conductors up to 2x 2.5 mm² or stranded up to 2x 25 mm². Side-by-side mounting is permitted, which saves panel width when ganging multiple contactors — no required air gap between units.

Environmental and compliance data

The contactor carries a RoHS substance prohibition date of 05/01/2012, indicating compliance with the EU RoHS directive. Front-of-device protection is IP20; the terminal area is IP00 (requires enclosure protection).

Coil and auxiliary ratings

The coil circuit is rated 48 V. Switching times: DC operate 20...30 ms, arcing time 10...15 ms. Auxiliary contact ratings at 24 V: 10 A; at 60 V: 2 A; at 110 V: 1 A; at 220 V: 0.3 A; at 230 V: 6 A; at 400 V: 3 A. Mechanical life of the contactor typical is 10 million operations. Maximum switching frequency varies by duty: AC-1 resistive loads up to 1,200 cycles/hour, AC-2 at 750, AC-3 at 1,000, AC-4 at 250 cycles/hour.

Frequently asked questions

Where can I buy 3RT1034-3BW40 and how is it quoted?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quotation.

What is the closest functional second-source to 3RT1034-3BW40?

The 3RT5034-1BW40 is a SIRIUS contactor in the same Size S2 frame with similar AC-3 power ratings, but it uses spring-cage terminals instead of screw terminals — check terminal compatibility before substituting.

What compliance documentation does 3RT1034-3BW40 carry?

RoHS compliance is confirmed with a substance prohibition date of 05/01/2012. The contactor is designed to IEC 60947-1 (pollution degree 3) and mounts on DIN rail per EN 50022.

Will 3RT1034-3BW40 drop into a panel specified around 3RT1044-1FB46?