Skip to main content
Siemens 3RT1035-1AB00 — Contactors

Siemens 3RT1035-1AB00 SIRIUS Power Contactor, Size S2, 22 kW

MPN3RT1035-1AB00

Siemens SIRIUS 3RT1035-1AB00 power contactor, Size S2, screw terminals, 22 kW at 500 V AC-3, 55 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1AB00 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1AB00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1AB00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1035-1AB00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-1AB00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1AB00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1AB00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1AB00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1AB00 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1035-1AB00 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Its headline motor rating is 22 kW at 500 V under AC-3 duty (cites:), which means it handles the inrush and running current of a standard three-phase induction motor up to that power — the rating that governs real-world motor switching, not the higher AC-1 resistive rating. For heavy-duty jogging or plugging (AC-4), it is rated 35 A at 400 V (cites:), so it can withstand the higher electrical wear of frequent reversals without premature contact degradation.

The 55 mm width (cites:) and 112 mm height (cites:) fit standard panel layouts; depth is 115 mm (cites:). Terminals are screw-type for the main circuit (cites:), accepting stranded conductors up to 2x 25 mm² (cites:) and solid up to 2x 4 mm² (cites:). IP20 on the front (cites:) means finger-safe in the enclosure; the terminal area is IP00 (cites:), so live parts are exposed outside the panel — plan for a proper enclosure door.

Sourcing Posture

No last-time-buy or surplus dependency applies. For a panel originally specified around the 3RT1036-1AB00 (a higher-rated sibling), this unit will not drop in without rewiring: the 3RT1036 is a larger frame with different terminal spacing and current capacity. Stick with the code on your schematic.

Frequently asked questions

What are the key dimensions of the 3RT1035-1AB00?

Width is 55 mm, height is 112 mm, and depth is 115 mm (cites:,).

MPN
3RT1035-1AB00