Skip to main content
Siemens 3RT1035-1AC24 — Contactors

Siemens 3RT1035-1AC24 SIRIUS Power Contactor, 24 V AC Coil,

MPN3RT1035-1AC24

Siemens SIRIUS power contactor, 3RT1035-1AC24, size S2, 24 V AC 50/60 Hz coil, screw terminals, 18.5 kW at 400 V AC-2, 55 x 112 x 164 mm, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1AC24 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1AC24 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1AC24 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1035-1AC24 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-1AC24 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1AC24 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1AC24 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1AC24 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1AC24 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1035-1AC24 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It carries an AC-2 rating of 18.5 kW at 400 V, which covers slip-ring motor duty where starting current and switching frequency are moderate — common on crane drives, hoists, and some mill auxiliaries. The coil is 24 V AC, rated at both 50 Hz and 60 Hz, with an operating range of 0.8 to 1.1 times rated voltage at 50 Hz and 0.85 to 1.1 at 60 Hz, so it holds in through the dips you see on a loaded line.

The 55 mm width and 112 mm height fit a standard S2 footprint; depth is 164 mm, which matters when you are laying out gland plates or enclosure depth against a backpanel.

Terminal wiring and environmental limits

Main circuit terminals are screw-type, accepting solid conductors from 2x 0.5 to 4 mm² and stranded from 2x 0.75 to 25 mm². That stranded range covers most power feeds up to 4 AWG, so you are not fighting undersized terminals on a 20 A motor circuit. The enclosure is IP20 on the front (finger-safe when panel door is closed) and IP00 at the terminals — bare metal inside the cabinet, which is normal for a panel-mounted contactor. Operating temperature range is -25 to +60 °C, storage -55 to +80 °C; the upper operating limit of 60 °C is adequate for most ventilated enclosures, but if this sits near a furnace zone or unvented cabinet, you will want to check the thermal curve for AC-3 duty cycles.

Frequently asked questions

What is the 3RT1035-1AC24 used for?

It is a SIRIUS power contactor rated for switching motor loads, particularly slip-ring motors under AC-2 duty (18.5 kW at 400 V), as well as resistive loads under AC-1. It is suited for control panels in industrial automation, material handling, and mill auxiliary drives.

Where can I buy the 3RT1035-1AC24?

The 3RT1035-1AC24 is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What are the key ratings of the 3RT1035-1AC24?

Key ratings include 18.5 kW at 400 V AC-2, a 24 V AC coil rated at 50/60 Hz, operating range of 0.8 to 1.1 times rated voltage at 50 Hz, screw terminals accepting stranded wire up to 25 mm², and an operating temperature range of -25 to +60 °C.

Will the 3RT1035-1AC24 drop into a panel specified for a 3RT1044-1FB46?

The 3RT1035-1AC24 is a size S2 contactor with a 55 mm width, while the 3RT1044-1FB46 is a different frame size. They are not direct drop-in replacements; you would need to verify panel cutout dimensions, terminal layouts, and coil voltage compatibility before substituting.

MPN
3RT1035-1AC24