Siemens 3RT1035-1AK60-ZW96 — Contactors

Siemens SIRIUS 3RT1035-1AK60-ZW96 Power Contactor, S2, 22 kW

MPN3RT1035-1AK60-ZW96

Siemens SIRIUS power contactor, size S2, 3RT1035-1AK60-ZW96, 22 kW at 500 V AC-3, screw terminals, 55 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1AK60-ZW96 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1AK60-ZW96 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1AK60-ZW96 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1035-1AK60-ZW96 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-1AK60-ZW96 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1AK60-ZW96 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1AK60-ZW96 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1AK60-ZW96 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1AK60-ZW96 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1035-1AK60-ZW96 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It carries a 22 kW rating at 500 V AC-3 duty, which is the standard motor-switching category for squirrel-cage motors — meaning it handles starting and stopping under load up to that power. At 400 V AC-2 (slip-ring motor duty) it's rated for 18.5 kW, and at 690 V it still delivers 11.4 kW, so it covers a wide voltage range across European and North American line voltages. The auxiliary contact block is rated 10 A at 24 V, 6 A at 230 V, and 0.3 A at 220 V DC, covering both AC and DC control circuits. Mechanical life is rated at 10 million operations, with maximum switching rates of 1 000 operations per hour under AC-3 and 1 200 under AC-1 resistive loads.

Mounting, wiring, and environmental fit

Width is 55 mm, depth 115 mm, height 112 mm, so it fits standard S2 contactor footprints. Main circuit wiring uses screw-type terminals accepting 2x (0.75... 25 mm²) stranded or 2x (0.5... 4 mm²) solid. Rated for pollution degree 3 (industrial environments with conductive or dry non-conductive pollution).

Frequently asked questions

What are the key power ratings for this contactor?

AC-3 motor duty: 22 kW at 500 V, 18.5 kW at 400 V AC-2, and 11.4 kW at 690 V. Auxiliary contacts handle 10 A at 24 V AC and 0.3 A at 220 V DC.

Does this contactor mount on standard DIN rail?

Yes, it mounts via screw or snap-on onto 35 mm DIN rail per EN 50022, and side-by-side mounting is allowed with no spacing requirement.

What wire sizes does the main circuit accept?

Screw terminals accept 2x (0.75... 25 mm²) stranded or up to 2x (0.75... 4 mm²) solid per terminal.

How does the 3RT1035-1AK60-ZW96 compare to the 3RT1036-1AB00?

The 3RT1036-1AB00 is a physically larger frame (size S3 vs S2) with higher current ratings. It will not drop into a panel cutout or DIN rail footprint designed for the S2 3RT1035 without reworking the mounting and bus bars. The 3RT1035 is the correct size for 22 kW at 500 V; the 3RT1036 handles higher loads.

MPN
3RT1035-1AK60-ZW96