Siemens 3RT1035-1AN20 SIRIUS Power Contactor, 22 kW AC-3

MPN3RT1035-1AN20

Siemens SIRIUS power contactor, 3RT1035-1AN20, size S2, 22 kW AC-3 at 500 V, 18.5 kW AC-2 at 400 V, screw terminals, 55 mm width, snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1AN20 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1AN20 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1AN20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RT1035-1AN20 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-1AN20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1AN20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1AN20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1AN20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1AN20 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1035-1AN20 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Rating and fit

The Siemens 3RT1035-1AN20 is a SIRIUS power contactor in the S2 frame size, rated for 22 kW at 500 V in AC-3 duty — that's the motor-switching rating that governs most conveyor, pump, and fan applications. At 400 V AC-2 it carries 18.5 kW, and at 690 V AC-4 it handles 11.4 kW, covering reversing or inching loads where the contactor makes and breaks under full current. The main circuit uses screw-type terminals, accepting solid conductors from 2x 0.5 to 1.5 mm² up to 2x 0.75 to 4 mm², and stranded up to 2x 25 mm². That covers most panel wiring from control to power feeds without needing lug adapters. Auxiliary contact ratings are specified: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V, and 3 A at 400 V — all at 50/60 Hz. These cover PLC input sensing and relay interlocking in the same panel without a separate auxiliary block.

Switching frequency and thermal limits

Maximum switching frequency depends on duty class: 1 200 operations per hour at AC-1 (resistive), 600 at AC-2, 1 000 at AC-3, and 300 at AC-4. For a typical AC-3 motor start, that's one cycle every 3.6 seconds — fine for most process cycling but not for high-speed jogging. The IP20 front enclosure protects against finger contact, while the terminals themselves are IP00 — meaning the wiring zone is open and must be inside a panel or enclosure. Operating time at AC coil is 7 to 20 ms, arcing time 10 to 15 ms.

Frequently asked questions

What are the key motor ratings for this contactor?

AC-3 duty: 22 kW at 500 V, 50/60 Hz. AC-2 duty: 18.5 kW at 400 V. AC-4 duty: 11.4 kW at 690 V. These are the ratings that determine motor load fit.

What is the physical size and mounting method?

The contactor is 55 mm wide, 112 mm high, and 115 mm deep. It mounts via screw and snap-on onto a 35 mm DIN rail per EN 50022. Side-by-side mounting is allowed without derating.

What wire sizes does the screw terminal accept?

Solid: 2x 0.5 to 1.5 mm², 2x 0.75 to 2.5 mm², max 2x 0.75 to 4 mm². Stranded: 2x 0.75 to 25 mm². Solid or stranded: 2x 0.75 to 16 mm².

What is the switching frequency capability?

AC-1: 1 200 ops/h, AC-2: 600 ops/h, AC-3: 1 000 ops/h, AC-4: 300 ops/h. Mechanical life is 10 000 000 operations typical.

MPN
3RT1035-1AN20