Siemens 3RT1035-1AP64 — Contactors

Siemens 3RT1035-1AP64 SIRIUS Power Contactor, 22 kW AC-3

MPN3RT1035-1AP64

Siemens SIRIUS power contactor, 3RT1035-1AP64, size S2, 22 kW at 400 V AC-3, screw-type terminals, 55 mm wide, snap-on DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1AP64 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1AP64 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1AP64 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RT1035-1AP64 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-1AP64 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1AP64 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1AP64 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1AP64 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1AP64 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1035-1AP64 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

The Siemens SIRIUS 3RT1035-1AP64 is a size S2 power contactor rated for 22 kW at 400 V in AC-3 duty and 18.5 kW at 400 V in AC-2 duty, making it a fit for motor switching in pump, fan, and conveyor applications where the load is predominantly inductive. The 55 mm wide frame snaps onto a 35 mm DIN rail per EN 50022, and the front face carries an IP20 rating while the terminal area is IP00 — standard for panel-mounted contactors where the enclosure provides the environmental seal.

AC-3 rating at 22 kW / 400 V is the headline number — this contactor switches squirrel-cage motors up to that load without welding the main contacts during inrush. The AC-2 rating of 18.5 kW at 400 V covers slip-ring motor starting, where the current stays closer to full-load during acceleration. For resistive loads (AC-1), the maximum operating rate is 1 200 cycles per hour; for AC-3 it drops to 1 000 cycles per hour, and for the punishing AC-4 plugging/reversing duty it is 300 cycles per hour — the thermal capacity of the S2 frame limits how fast you can slam it in and out under load. The auxiliary contact ratings cover a 24 V DC control circuit at 10 A, stepping down to 0.3 A at 220 V DC — useful for interlocking with a PLC output or a safety relay. The coil operates between 0.8 and 1.1 times the rated voltage at both 50 Hz and 60 Hz, so a 208-240 V control transformer is fine; the 7 to 20 ms closing time and 10 to 15 ms arcing time are typical for this frame size. The screw-type main circuit terminals accept stranded wire up to 2x 25 mm², and the solid/stranded auxiliary terminals handle 2x 0.5 to 4 mm².

Frequently asked questions

What are the key ratings for this contactor?

AC-3 motor switching at 22 kW at 400 V, AC-2 at 18.5 kW at 400 V, and AC-3 at 690 V at 11.4 kW. The coil operates at 50/60 Hz with a 0.8 to 1.1 voltage tolerance.

What mounting and terminal type does it use?

It mounts via screw and snap-on onto a 35 mm DIN rail per EN 50022. Main circuit terminals are screw-type, accepting stranded wire up to 2x 25 mm².

MPN
3RT1035-1AP64