Skip to main content
Siemens 3RT1035-1AR60-1AA0 — Contactors

Siemens 3RT1035-1AR60-1AA0 SIRIUS Power Contactor, Size S2,

MPN3RT1035-1AR60-1AA0

Siemens SIRIUS, power contactor, Size S2, 3RT1035-1AR60-1AA0, 400 V 50 Hz, screw-type terminals, 55 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1AR60-1AA0 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1AR60-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1AR60-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz400 V
3RT1035-1AR60-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-1AR60-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1AR60-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1AR60-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1AR60-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1AR60-1AA0 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1035-1AR60-1AA0 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

The Siemens 3RT1035-1AR60-1AA0 is a SIRIUS power contactor in the Size S2 frame, rated for 400 V at 50 Hz and 400...440 V at 60 Hz. It is a current-production part, still in active manufacture. This contactor switches motor loads: at AC-2 duty (slip-ring motors, soft-start) it handles 18.5 kW at 400 V; at AC-3 duty (squirrel-cage motors, direct-on-line) it handles 22 kW at 500 V; at AC-4 duty (plugging, inching) it handles 11.4 kW at 690 V.

Main current circuit terminals are screw-type, accepting solid conductors: 2x (0.5...1.5 mm²), 2x (0.75...2.5 mm²), max 2x (0.75...4 mm²). Stranded conductors accept 2x (0.75...25 mm²), and the combined solid-or-stranded range is 2x (0.75...16 mm²). This covers most panel wiring from control-circuit tails to motor feeders.

Coil and auxiliary contact ratings

Auxiliary contact ratings are given for DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V. These are the make/break limits for the built-in aux contacts — useful for interlocking and PLC inputs. Maximum switching frequency varies by duty: 1,200 cycles/hour at AC-1 (resistive), 1,000 at AC-3, 600 at AC-2, and 300 at AC-4. The AC-4 limit reflects the heavier arc wear during plugging/reversing.

Frequently asked questions

What are the key motor ratings for 3RT1035-1AR60-1AA0?

At AC-3 duty it handles 22 kW at 500 V; at AC-2 duty it handles 18.5 kW at 400 V; at AC-4 duty it handles 11.4 kW at 690 V.

Where can I buy 3RT1035-1AR60-1AA0?

This part is sourced and quoted to order against an RFQ through independent distribution channels. Availability and current pricing are confirmed at the time of quote.

What is the difference between 3RT1035-1AR60-1AA0 and 3RT5034-1AR60?

The 3RT5034-1AR60 is a Size S3 frame contactor with higher current ratings, so it is physically larger and will not drop into a panel wired for the Size S2 3RT1035-1AR60-1AA0 without rewiring and re-paneling. The 3RT1035-1AR60-1AA0 is the correct fit for Size S2 cutouts and buswork.

MPN
3RT1035-1AR60-1AA0