Siemens SIRIUS 3RT1035-1XF40-0LA2 Power Contactor, S2, 110 V

MPN3RT1035-1XF40-0LA2

Siemens SIRIUS power contactor, size S2, 3RT1035-1XF40-0LA2, 110 V AC coil, screw-type terminals, 22 kW at 500 V AC-3, 55 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-1XF40-0LA2 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-1XF40-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-1XF40-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1035-1XF40-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT1035-1XF40-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-1XF40-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-1XF40-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-1XF40-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-1XF40-0LA2 — Mechanical
ParameterValue
Width55 mm
Height142 mm
Depth130 mm

Product details

SIRIUS S2 Power Contactor with 110 V AC Coil

The coil is rated for 110 V AC, picking up at 70% of rated voltage and dropping out at 125% of rated value.

Motor Switching Capacity and Duty Cycles

This contactor is rated for 22 kW at 500 V in AC-3 duty (standard motor switching) and 11.4 kW at 690 V. For AC-2 duty (slip-ring motor starting) at 400 V, it handles 18.5 kW. Switching frequency varies by duty: up to 1 200 operations per hour for AC-1 resistive loads, 1 000/h for AC-3 motor loads, 600/h for AC-2, and 300/h for AC-4 (plugging/inching).

Auxiliary and DC Switching Capability

The contactor carries zero instantaneous auxiliary contacts (no built-in aux), so any auxiliary switching requires a separate add-on block. For DC loads, it is rated at 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, and 0.3 A at 220 V — these are the maximum breaking currents for DC circuits, which are significantly lower than AC ratings due to arc extinction characteristics.

Main circuit connections use screw-type terminals. Solid conductors: 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded conductors: 2x (0.75 to 25 mm²). For the main circuit at maximum AC-1 rating, the terminal accepts up to 16 mm². Solid or stranded combinations: 2x (0.75 to 16 mm²). These ranges cover typical panel wiring from control to power circuits.

Physical Dimensions and Mounting Clearances

Dimensions: 55 mm width, 142 mm height, 130 mm depth. Side-by-side mounting is permitted, which saves panel space. The 55 mm width is the standard S2 footprint — check your panel layout against this dimension.

Frequently asked questions

What are the main circuit termination details for this contactor?

Screw-type terminals accept solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (0.75 to 25 mm²). Max AC-1 termination: 16 mm².

What is the physical size of this contactor?

Width 55 mm, height 142 mm, depth 130 mm. Side-by-side mounting is allowed. Required clearances: 10 mm in all directions (up, down, forward, side).

What motor power can this contactor switch?

22 kW at 500 V AC-3 (standard motor switching), 11.4 kW at 690 V AC-3, and 18.5 kW at 400 V AC-2 (slip-ring motor starting).