Siemens 3RT1035-3AG18-0PA3 — Contactors

Siemens 3RT1035-3AG18-0PA3 SIRIUS Power Contactor, Size S2,

MPN3RT1035-3AG18-0PA3

Siemens SIRIUS 3RT1035-3AG18-0PA3, Size S2 power contactor, screw-type terminals, 22 kW at 500 V AC-3, 85 x 112 x 115 mm, DIN-rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1035-3AG18-0PA3 — Identification
ParameterValue
Contactor frame sizeS2
3RT1035-3AG18-0PA3 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V35 A
Rated value @ 400 V3 A
Rated value @ 500 V22 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1035-3AG18-0PA3 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz100 V
3RT1035-3AG18-0PA3 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1035-3AG18-0PA3 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 125 A
Short-circuit coordination type 2, fusefuse gL/gG: 63 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1035-3AG18-0PA3 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1035-3AG18-0PA3 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1035-3AG18-0PA3 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1035-3AG18-0PA3 — Mechanical
ParameterValue
Width85 mm
Height112 mm
Depth115 mm
3RT1035-3AG18-0PA3 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It switches motor loads up to 22 kW at 500 V in AC-3 duty, or 11.4 kW at 690 V. For AC-4 (inching/plugging) the rating is 35 A at 400 V. AC-3 is the standard motor-switching category — the 22 kW figure at 500 V tells you the contactor handles full-load motor starts without welding the contacts. The 690 V rating (11.4 kW) covers higher-voltage European or Canadian industrial supplies.

Dimensions are 85 mm wide, 112 mm high, 115 mm deep — the Size S2 footprint is the standard for this current class.

Screw-type terminals accept 2 x (0.25 to 2.5 mm²) solid or 2 x (0.75 to 25 mm²) stranded. The 25 mm² upper end on stranded means it can take a heavy feeder cable without needing a lug adapter — useful for the main power path.

Operating conditions and ratings

Coil operates on 50/60 Hz. Maximum switching rates vary by duty: 1200 cycles/hour AC-1, 600 AC-2, 1000 AC-3, 300 AC-4.

Frequently asked questions

What are the key power ratings for this contactor?

AC-3 motor switching: 22 kW at 500 V, 11.4 kW at 690 V. AC-4 (inching/plugging): 35 A at 400 V. AC-2 at 400 V: 18.5 kW.

What is the physical size and mounting?

Size S2 footprint: 85 mm wide, 112 mm high, 115 mm deep. Mounts on 35 mm DIN rail per DIN EN 50022, screw or snap-on. Side-by-side mounting allowed.

What wire sizes does the screw terminal accept?

Solid: 2 x (0.25 to 2.5 mm²). Stranded: 2 x (0.75 to 25 mm²). The 25 mm² stranded capacity handles heavy power feeders directly.

What is the closest functional alternative to this contactor?

The 3RT1034-1AN60-1AA0 is a smaller Size S0 contactor — it will not drop into the same panel footprint without re-drilling or changing the DIN-rail layout. The 3RT1036-1AB00 is the next size up (S3) for higher current. For a direct Size S2 replacement with similar ratings, this 3RT1035-3AG18-0PA3 is the correct fit.

MPN
3RT1035-3AG18-0PA3