Siemens 3RT1036-1AD24 — Contactors

Siemens 3RT1036-1AD24 SIRIUS Power Contactor, S2, 42V 50/60H

MPN3RT1036-1AD24

Siemens SIRIUS power contactor, size S2, 42 V 50/60 Hz coil, screw-type terminals, 22 kW AC-3 at 400 V, 55 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-1AD24 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-1AD24 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-1AD24 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz42 V
3RT1036-1AD24 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-1AD24 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-1AD24 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-1AD24 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-1AD24 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-1AD24 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1036-1AD24 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

SIRIUS 3RT1036-1AD24 — S2 Power Contactor, 42 V Coil

Side-by-side mounting is supported, so multiple contactors can be ganged without additional spacing.

The headline motor power rating is 22 kW under AC-3 at 400 V — this is the rating that governs switching of standard squirrel-cage motors during starting and running. For resistive loads (AC-1), the switching frequency reaches 1 000 cycles per hour, while AC-3 allows 800 cycles per hour, reflecting the higher electrical stress of motor inrush currents. Auxiliary contact ratings are provided across a range of control voltages: 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V. These cover typical PLC output or relay interface circuits. The main power terminals accept solid conductors up to 4 mm² (2x) and stranded conductors up to 25 mm² (2x), which covers most motor feeder cables up to the 22 kW range.

The coil operates reliably between 0.8 and 1.1 times rated voltage at 50 Hz, and 0.85 to 1.1 at 60 Hz, providing a reasonable tolerance for supply fluctuations.

Dimensions are 112 mm height, 55 mm width, and 164 mm depth. The depth is the critical dimension for enclosure depth selection — ensure at least 170 mm clear depth behind the mounting plate for wiring and arc clearance. The S2 frame size is a common Siemens footprint, so auxiliary contact blocks and overload relays from the SIRIUS family will mount directly without adapters.

Frequently asked questions

What are the key power ratings for motor switching?

The contactor is rated 22 kW at 400 V under AC-3 duty (standard motor starting). At 500 V it is rated 30 kW, and at 690 V it is rated 11.4 kW. For AC-2 duty (slip-ring motors) it is rated 22 kW at 400 V.

What is the coil voltage and frequency?

The coil is rated 42 V at 50 Hz and 42 V at 60 Hz. The operating range is 0.8 to 1.1 times rated voltage at 50 Hz, and 0.85 to 1.1 at 60 Hz.

What conductor sizes does the terminal accept?

For solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). For stranded conductors: 2x (0.75 to 25 mm²). There is also a combined solid/stranded range of 2x (0.75 to 16 mm²).

What are the mounting options?

The contactor mounts via screw fixing or snap-on onto a 35 mm DIN rail per EN 50022. Side-by-side mounting is supported without additional spacing.