Siemens SIRIUS 3RT1036-1AH20-1AA0 Power Contactor, S2, 22kW

MPN3RT1036-1AH20-1AA0

Siemens SIRIUS power contactor, 3RT1036-1AH20-1AA0, size S2, screw terminals, 22 kW at AC-2 400 V, 30 kW at 500 V, 11.4 kW at 690 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-1AH20-1AA0 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-1AH20-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-1AH20-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1036-1AH20-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-1AH20-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-1AH20-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-1AH20-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-1AH20-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-1AH20-1AA0 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1036-1AH20-1AA0 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

For motor duty, the key rating is 22 kW at AC-2 utilization category at 400 V, which covers slip-ring motors and wound-rotor applications. It also handles 30 kW at 500 V and 11.4 kW at 690 V, giving flexibility across supply voltages common in European and export panels. The AC-3 rating at 400 V is 30 kW, covering standard squirrel-cage motors.

Mechanical and Electrical Fit

Dimensions are 112 mm height, 55 mm width, and 115 mm depth. The 55 mm width is the S2 standard — it occupies three 18 mm modular positions on the DIN rail, so check your enclosure fill factor. Side-by-side mounting is permitted, which saves rail space in multi-contactor groups. Solid wire capacity is 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), max 2x (0.75…4 mm²). Stranded accepts 2x (0.75…25 mm²), and solid or stranded goes up to 2x (0.75…16 mm²). That covers most panel wiring from control circuits up to motor feeders.

The contactor is rated for 50/60 Hz operation with a voltage tolerance of 0.8…1.1 at 50 Hz and 0.85…1.1 at 60 Hz. Mechanical endurance is typical 10,000,000 operations, with maximum switching rates varying by duty: AC-1 at 1000 1/h, AC-3 at 800 1/h, AC-4 at 300 1/h.

Frequently asked questions

What are the key motor ratings for this contactor?

The contactor is rated 22 kW at AC-2 400 V, 30 kW at AC-3 400 V, 30 kW at 500 V, and 11.4 kW at 690 V. These cover the most common motor voltages in industrial panels.

What wire sizes does this contactor accept?

Screw terminals accept solid wire 2x (0.5…1.5 mm²), 2x (0.75…2.5 mm²), max 2x (0.75…4 mm²). Stranded wire accepts 2x (0.75…25 mm²). Solid or stranded up to 2x (0.75…16 mm²).