Siemens 3RT1036-1AK64-3MA0 — Contactors

Siemens 3RT1036-1AK64-3MA0 SIRIUS Power Contactor, Size S2,

MPN3RT1036-1AK64-3MA0

Siemens SIRIUS power contactor, 3RT1036-1AK64-3MA0, Size S2, screw-type terminals, 22 kW at AC-2 400V, 30 kW at 500V, 55 mm wide, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-1AK64-3MA0 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-1AK64-3MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-1AK64-3MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1036-1AK64-3MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-1AK64-3MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-1AK64-3MA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-1AK64-3MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-1AK64-3MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-1AK64-3MA0 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1036-1AK64-3MA0 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It's rated for 22 kW at AC-2 duty on 400 V, and can handle 30 kW at 500 V or 11.4 kW at 690 V, so it covers a solid range of three-phase induction motors across common European and North American supply voltages. At 55 mm wide, it fits a standard panel slot without crowding adjacent devices. It's rated for both 50 Hz and 60 Hz supply, with an operating factor of 0.8 to 1.1 at either frequency.

If your line has a motor starting under load or reversing frequently, AC-2 is the duty class you need, and this contactor delivers it. The auxiliary contact block handles 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V, so it can drive smaller relays or PLC inputs directly without an interposing relay in most panels.

Wiring and integration notes

Screw terminals on the main circuit accept 2x (0.75 to 25 mm²) stranded, or 2x (0.5 to 4 mm²) solid. The auxiliary terminals take 2x (0.75 to 16 mm²) solid or stranded. That covers most panel wiring from control to power feeds without needing adapters.

Frequently asked questions

What wire sizes does the 3RT1036-1AK64-3MA0 accept?

The main circuit screw terminals accept 2x (0.75 to 25 mm²) stranded wire, or 2x (0.5 to 4 mm²) solid wire. The auxiliary terminals accept 2x (0.75 to 16 mm²) solid or stranded.

MPN
3RT1036-1AK64-3MA0