Siemens 3RT1036-1AN00 — Contactors

Siemens SIRIUS 3RT1036-1AN00 Power Contactor, 22 kW AC-2, 41

MPN3RT1036-1AN00

Siemens SIRIUS, power contactor, 3RT1036-1AN00, size S2, screw terminals, 22 kW at AC-2 400 V, 41 A AC-4, 55 mm width, 112 mm height, 115 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-1AN00 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-1AN00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-1AN00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RT1036-1AN00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-1AN00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-1AN00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-1AN00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-1AN00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-1AN00 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1036-1AN00 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

At 500 V it is rated 30 kW, and at 690 V it is rated 11.4 kW. The contactor is rated for an operating temperature range of -25 °C to +60 °C, storage from -55 °C to +80 °C, and pollution degree 3.

The RoHS compliance date is listed as 05/01/2012, meaning the design meets the substance prohibitions effective from that date.

Terminal sizing and wiring

The screw terminals accept solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²). Stranded conductors: 2x (0.75 to 25 mm²). Solid or stranded: 2x (0.75 to 16 mm²). At 40 °C the minimum permissible cross-section is 16 mm².

Mechanical and electrical endurance

Mechanical life is typical 10,000,000 operations. Maximum switching rates: AC-1 at 1,000 cycles/h, AC-2 at 400 cycles/h, AC-3 at 800 cycles/h, AC-4 at 300 cycles/h. Arcing time is 10 to 15 ms; the AC operating range is 0.8 to 1.1 at 50 Hz.

Frequently asked questions

What is 3RT1036-1AN00's listed depth (115 mm) on this component line?

The depth is 115 mm.

What is 3RT1036-1AN00's listed solid (2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²), max. 2x (0.75... 4 mm²)) on this component line?

The solid conductor capacity is 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), and max 2x (0.75 to 4 mm²).

Will 3RT1036-1AN00 drop into a panel that was specified around 3RT5036-1AP00 without rewiring?

Yes, both are size S2 contactors with the same DIN-rail mounting footprint per EN 50022, so the mechanical fit is identical. The only difference is the terminal type: screw on the 3RT1036-1AN00 versus spring-cage on the 3RT5036-1AP00. If the panel wiring is already terminated with ferrules or bare stranded wire, the screw terminals accept the same conductor sizes without rewiring.

MPN
3RT1036-1AN00