Siemens 3RT1036-1AT60 SIRIUS Power Contactor, S2 Frame, 22 k

MPN3RT1036-1AT60

Siemens SIRIUS power contactor, S2 frame, screw-type terminals, 22 kW AC-2 at 400 V, 41 A AC-4, IP20 front, DIN EN 50022 rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-1AT60 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-1AT60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-1AT60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1036-1AT60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-1AT60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-1AT60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-1AT60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-1AT60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-1AT60 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth115 mm
3RT1036-1AT60 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Part identification and mounting

Motor switching ratings and duty cycles

For AC-4 (inching/plugging) the contactor carries 41 A at 400 V, which is the higher thermal stress case. Maximum switching rates are 400 cycles/hour for AC-2 and 300 cycles/hour for AC-4, so this part is not intended for high-speed jogging applications.

Coil and auxiliary ratings

The coil operates at 24 V rated value drawing 10 A — this is the inrush current for the solenoid, not the holding current. At 230 V rated value the auxiliary contacts carry 6 A, suitable for pilot duty in control circuits. The contactor's mechanical life is typically 10 million operations, with electrical life dependent on the switching category and load current.

The front of the contactor is rated IP20 (finger-safe terminals), while the terminal area itself is IP00 — panel builders must account for this in the enclosure design. RoHS compliance is evidenced by the substance prohibition date of 05/01/2012.

Frequently asked questions

Where can I buy 3RT1036-1AT60 and how do I get a price?

This part is sourced through independent industrial distribution channels. Submit an RFQ for current pricing and availability confirmation at the time of your order.

What is 3RT1036-1AT60's listed depth?

The overall depth is 115 mm, with a width of 55 mm and height of 112 mm, fitting the S2 frame footprint.

What compliance documentation does this brand provide for 3RT1036-1AT60?

The manufacturer provides RoHS compliance with a substance prohibition date of 05/01/2012. The contactor is designed to IEC 60947-4-1 with pollution degree 3. REACH and UL documentation should be requested at time of order for your specific jurisdiction.

Will 3RT1036-1AT60 drop into a panel specified around 3RT5036-1AP00 without rewiring?

Both are S2 frame contactors with the same mounting footprint on 35 mm DIN rail per EN 50022. The 3RT1036-1AT60 uses screw-type terminals for the main circuit, while the 3RT5036 series uses spring-cage terminals. If the panel was wired for screw terminals, the 3RT1036-1AT60 is a direct mechanical fit; if the panel uses spring-cage connectors, the terminal type differs and wiring adaptation is required.

MPN