Siemens 3RT1036-1XF40-0LA2 — Contactors

Siemens 3RT1036-1XF40-0LA2 SIRIUS Power Contactor, 110 V Coi

MPN3RT1036-1XF40-0LA2

Siemens SIRIUS, power contactor, 3RT1036-1XF40-0LA2, Size S2, 110 V AC coil, screw-type terminals, 30 kW at 500 V AC-3, 55 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-1XF40-0LA2 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-1XF40-0LA2 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-1XF40-0LA2 — Control & Coil
ParameterValue
Control supply voltage typeDC
3RT1036-1XF40-0LA2 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
3RT1036-1XF40-0LA2 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-1XF40-0LA2 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-1XF40-0LA2 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-1XF40-0LA2 — Environmental
ParameterValue
Operating temperature range-40 ... +70 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-1XF40-0LA2 — Mechanical
ParameterValue
Width55 mm
Height142 mm
Depth130 mm

Product details

The Siemens SIRIUS 3RT1036-1XF40-0LA2 is a Size S2 power contactor with a 110 V rated coil, designed for screw and snap-on mounting onto 35 mm standard mounting rail per DIN EN 50022. It carries a 30 kW motor rating at 500 V in AC-3 duty and 11.4 kW at 690 V, making it a fit for medium-horsepower motor switching in control panels.

The AC-3 rating of 30 kW at 500 V defines the contactor's ability to switch three-phase induction motors on and off under full load — that's the number to match against your motor nameplate. At 690 V the same duty drops to 11.4 kW, reflecting the higher arc energy at elevated voltage. For AC-2 duty (slip-ring motor starting), the rating is 22 kW at 400 V, which covers wound-rotor applications where the contactor handles starting current without full-load interruption. That's enough for frequent start-stop cycles on conveyors or pumps without wearing out the mechanism prematurely. Arcing time sits at 10 to 15 ms, and DC operating time is 20 to 25 ms — fast enough for most sequencing requirements. The auxiliary contact block handles 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V — sufficient for signaling back to a PLC or for interlocking with other contactors in a motor control center. The coil pick-up threshold is 0.7 of rated voltage, and drop-out is at 1.25 of rated, ensuring reliable operation even with slight voltage sags on the control transformer.

Side-by-side mounting is allowed, saving rail space when grouping multiple contactors in a motor control center. Clearance requirements are 10 mm upwards, downwards, forwards, and to the side — tight enough for dense panel layouts. Main circuit terminals are screw-type, accepting 2x (0.75 to 25 mm²) stranded or 2x (0.75 to 16 mm²) solid/stranded wire. The maximum cross-section at AC-1 rated current is 16 mm². Auxiliary terminals accept 2x (0.5 to 1.5 mm²) solid, 2x (0.75 to 2.5 mm²) solid, or max 2x (0.75 to 4 mm²) — standard for control wiring. Strip length and torque values follow the terminal marking on the contactor.

Frequently asked questions

What are the key ratings for 3RT1036-1XF40-0LA2?

This Size S2 contactor is rated for 30 kW at 500 V AC-3, 11.4 kW at 690 V AC-3, and 22 kW at 400 V AC-2. The coil is 110 V rated. Mechanical life is 10 million operations typical.

What is the depth of 3RT1036-1XF40-0LA2?

The depth is 130 mm, with a width of 55 mm and height of 142 mm. Clearance requirements are 10 mm on all sides.

What wire sizes does the 3RT1036-1XF40-0LA2 accept?

Main terminals accept 2x (0.75 to 25 mm²) stranded or 2x (0.75 to 16 mm²) solid/stranded. Auxiliary terminals accept 2x (0.5 to 1.5 mm²) solid, 2x (0.75 to 2.5 mm²) solid, or max 2x (0.75 to 4 mm²).

Where can I buy 3RT1036-1XF40-0LA2?

This part is sourced and quoted to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

MPN
3RT1036-1XF40-0LA2