SIRIUS S2 Power Contactor — 22 kW AC-2 at 400 V
For AC-3 duty (squirrel-cage motors, direct-on-line starts), it carries 30 kW at 500 V and 11.4 kW at 690 V, covering the common European motor voltage bands. Wire connections are screw-type terminals on the main circuit, accepting solid conductors from 2x 0.25 to 2.5 mm² and stranded from 2x 0.75 to 25 mm². The auxiliary contacts are rated for switching at 24 V (10 A), 110 V (1 A), and 230 V (6 A), covering typical PLC and relay interface levels.
Maximum switching frequencies vary by duty: 1,000 cycles/hour for AC-1 (resistive), 800 for AC-3 (motor start/run), 400 for AC-2, and 300 for AC-4 (plugging/inching). Dimensions are 55 mm wide, 112 mm high, and 115 mm deep — a compact S2 footprint that fits standard 55 mm-wide DIN-rail slots. The coil operates at 50/60 Hz with a voltage tolerance of 0.8 to 1.1 times the rated value.