Siemens 3RT1036-3AL24-1AA0 — Contactors

Siemens SIRIUS 3RT1036-3AL24-1AA0 Power Contactor, 22 kW AC-

MPN3RT1036-3AL24-1AA0

Siemens SIRIUS, power contactor, Size S2, 3RT1036-3AL24-1AA0, 22 kW at AC-2 400 V, screw-type terminals, IP20 front, IP00 terminal area.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-3AL24-1AA0 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-3AL24-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-3AL24-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1036-3AL24-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-3AL24-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-3AL24-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-3AL24-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-3AL24-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-3AL24-1AA0 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1036-3AL24-1AA0 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

Product Identification and Compliance

It is designed for screw-type terminal connections on the main current circuit.

Electrical Ratings and Application Context

The headline motor rating for this contactor is 22 kW at AC-2 duty at 400 V, 50/60 Hz. This is distinct from AC-3 (squirrel-cage motors) or AC-4 (plugging/inching) — the specifier must match the duty class to the load. For the control circuit, the contactor coil is rated for 50 Hz at 230 V and 60 Hz at 230 V. The operating range is 0.8 to 1.1 times the rated voltage at 50 Hz, and 0.85 to 1.1 at 60 Hz. The contactor will pick up reliably within these bands; below the lower threshold, dropout may occur. The auxiliary contact ratings are provided for DC switching: 10 A at 24 V, 2 A at 60 V, 1 A at 110 V, 0.3 A at 220 V, 6 A at 230 V AC, and 3 A at 400 V AC. These values govern the auxiliary circuit design — for example, a PLC 24 VDC output driving the coil must be rated for the inrush, not just the hold-in current. Mechanical endurance is listed at 10,000,000 operating cycles typical. The maximum switching frequency varies by duty: 1,000 cycles/hour at AC-1, 400 at AC-2, 800 at AC-3, and 300 at AC-4.

Side-by-side mounting is permitted, which allows dense panel layouts without mandatory spacing, provided the thermal derating is observed. Physical dimensions are 55 mm width, 112 mm height, and 164 mm depth. The depth of 164 mm must be accounted for in enclosure depth selection, particularly when a door-mounted disconnect or operator interface is present. Terminal capacity: solid 2x (0.25 to 2.5 mm²) for control; stranded 2x (0.75 to 25 mm²) for main circuit; stranded 2x (0.75 to 16 mm²) for auxiliary.

Frequently asked questions

Will the 3RT1036-3AL24-1AA0 drop into a panel specified around the 3RT1044-1FB46?

The 3RT1044-1FB46 is a different frame size and rating class. The 3RT1036 is a Size S2; the 3RT1044 is a larger frame. Panel cutouts, DIN rail spacing, and terminal positions differ. A direct drop-in without rewiring or re-drilling is not supported. Verify the physical dimensions and terminal layout against the existing panel design.

MPN
3RT1036-3AL24-1AA0