Siemens 3RT1036-3AP04-1AA0 — Contactors

Siemens 3RT1036-3AP04-1AA0 SIRIUS Power Contactor, 22 kW AC-

MPN3RT1036-3AP04-1AA0

Siemens SIRIUS 3RT1036-3AP04-1AA0 power contactor, S2 frame, 22 kW AC-2 at 400 V, 30 kW AC-3 at 500 V, screw terminals, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1036-3AP04-1AA0 — Identification
ParameterValue
Contactor frame sizeS2
3RT1036-3AP04-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V41 A
Rated value @ 400 V3 A
Rated value @ 500 V30 kW
Rated value @ 690 V11.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1036-3AP04-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1036-3AP04-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1036-3AP04-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 160 A
Short-circuit coordination type 2, fusefuse gL/gG: 80 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1036-3AP04-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (0.75 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm standard mounting rail according to DIN EN 50022
Side-by-side mountingYes
3RT1036-3AP04-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1036-3AP04-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1036-3AP04-1AA0 — Mechanical
ParameterValue
Width55 mm
Height112 mm
Depth164 mm
3RT1036-3AP04-1AA0 — Specifications
ParameterValue
At AC7 ... 20 ms

Product details

It is rated for AC-2 duty at 22 kW at 400 V, covering slip-ring motor applications, and AC-3 duty at 30 kW at 500 V for standard squirrel-cage motors. At 690 V AC-3, it handles 11.4 kW. Its dimensions are 55 mm wide, 112 mm high, and 164 mm deep, occupying a single modular slot.

This is the rating that governs contact life under heavy switching — not the AC-3 figure. The AC-1 maximum operating rate of 1000 cycles per hour applies to resistive loads; AC-4 drops to 300 cycles per hour due to arc erosion. The auxiliary contact ratings cover a wide control voltage range: 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V. The 24 V rating is the one to check for PLC-driven circuits — it confirms the contacts can handle typical 24 VDC solenoid loads without derating. This is standard for open panel mounting but requires the IP20 front cover for operator safety.

Main circuit terminals are screw-type, accepting 2x (0.75 to 25 mm²) stranded or 2x (0.25 to 2.5 mm²) solid. The 16 mm² minimum at 40 °C sets the smallest wire size for full rated current — use 16 mm² or larger for the power circuit to avoid terminal overheating. The IP00 terminal rating means the wiring area is not touch-safe — plan for finger-duct covers or shrouded terminals in the panel layout.

Frequently asked questions

What is the closest functional second-source — 3RT1036-1AB00?

The 3RT1036-1AB00 is a sibling in the same S2 frame size but lacks the auxiliary contact block suffix. The 3RT1036-3AP04-1AA0 includes factory-fitted auxiliary contacts (the -3AP04 suffix). For a drop-in replacement without rewiring, verify the auxiliary contact configuration matches your control circuit. The main power ratings and mounting footprint are identical.

What is the listed depth of this contactor?

The depth is 164 mm, measured from the DIN rail mounting surface to the furthest projection of the screw terminals.

What solid wire sizes does it accept?

The main terminals accept 2x (0.25 to 2.5 mm²) solid wire. For stranded wire, the range is 2x (0.75 to 25 mm²).

Will it drop into a panel specified around 3RT1036-1AB00 without rewiring?

Yes, the mounting footprint (55 mm width, DIN rail snap-on) and main power terminal locations are identical. The difference is the auxiliary contact configuration — the -3AP04 suffix adds specific auxiliary contacts. If the original BOM called for a separate auxiliary contact block, this integrated version may simplify wiring. Verify the contact arrangement matches your control schematic.

What compliance documentation is available?

The part is RoHS-compliant with a substance prohibition date of May 1, 2012, and REACH-compliant. It carries IP20 protection on the front and IP00 on the terminals. Pollution degree 3 per IEC 60947-1 applies. Standard Siemens SIRIUS documentation includes a CE declaration of conformity and UL/CSA file numbers.