Siemens 3RT1044-1AB00 SIRIUS Power Contactor, Size S3, 37 kW

MPN3RT1044-1AB00

Siemens SIRIUS power contactor, 3RT1044-1AB00, Size S3, screw-type terminals, 37 kW at 500 V AC-3, 70 mm width.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-1AB00 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-1AB00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-1AB00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1044-1AB00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-1AB00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-1AB00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-1AB00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-1AB00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-1AB00 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1044-1AB00 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

It's rated 37 kW at 500 V and 18.6 kW at 690 V under AC-3 duty — the motor-switching curve that matters for most conveyor, pump, and fan applications.

The main circuit uses screw-type terminals; solid wire accepts 2x (0.5 to 1.5 mm²) or 2x (0.75 to 2.5 mm²), and stranded goes up to 2x (10 to 50 mm²). That stranded range covers the main power feed for a 37 kW motor at 500 V — no need for lug adapters on the line side.

The AC-3 rating of 37 kW at 500 V is the headline number for motor switching — it tells you this contactor can handle a 37 kW induction motor on a 500 V line without welding contacts during normal starts. The AC-4 rating of 55 A at 400 V is the tougher duty cycle for reversing or jogging; if your application does frequent plugging, that 55 A figure is the one to size against, not the AC-3 kW number.

Frequently asked questions

What compliance documentation is available for 3RT1044-1AB00?

RoHS compliance is confirmed with a substance prohibitance date of May 1, 2012. The contactor carries a degree of pollution 3 rating for industrial environments. For specific UL, CSA, or IEC certificates, request the manufacturer's declaration with your RFQ.

What are the key ratings for this contactor?

AC-3 motor switching: 37 kW at 500 V, 18.6 kW at 690 V. AC-4 inching/plugging: 55 A at 400 V. Coil: 24 V at 50 Hz. Mechanical life: 10 million operations typical. Operating temperature: -25 to +60 °C.

Will 3RT1044-1AB00 drop into a panel specified for 3RT1044-1FB46?

Both are Size S3 SIRIUS contactors with the same 70 mm width and DIN-rail mounting, so the footprint and rail position are identical. The difference is in the coil voltage — the 1AB00 runs on 24 V at 50 Hz, while the 1FB46 uses a different coil. Verify your control voltage before swapping; if it's 24 V, the mechanical fit is direct.