Siemens 3RT1044-1AB04 — Contactors

Siemens 3RT1044-1AB04 SIRIUS Power Contactor, S3, 37 kW at 5

MPN3RT1044-1AB04

Siemens SIRIUS 3RT1044-1AB04 power contactor, size S3, screw-type terminals, 37 kW at 500 V, 55 A AC-4 at 400 V, snap-on 35/75 mm rail.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-1AB04 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-1AB04 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-1AB04 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1044-1AB04 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-1AB04 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-1AB04 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-1AB04 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-1AB04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-1AB04 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth188 mm
3RT1044-1AB04 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

It's rated 37 kW at 500 V for AC-3 duty, which covers most three-phase induction motors in that power band — conveyors, pumps, fans. For severe switching like reversing or inching (AC-4), it handles 55 A at 400 V, so it survives the arcing of frequent plugging without welding contacts.

The solid wire range is 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²), max. 2x (0.75... 4 mm²); stranded accepts 2x (10... 50 mm²). That's enough cross-section for the 55 A AC-4 current without doubling up lugs.

Operating conditions and durability

Frequently asked questions

What are the key power ratings?

AC-3 motor rating is 37 kW at 500 V; AC-4 severe-duty rating is 55 A at 400 V. Coil is 24 V at 50 Hz.

What is the mounting and wire size?

Snap-on for 35 mm or 75 mm DIN rail. Main terminals accept solid 2x (0.5... 1.5 mm²) up to max 2x (0.75... 4 mm²), and stranded 2x (10... 50 mm²). Screw-type terminals.

Will this drop into a panel designed for a 3RT1036-1AB00?

The 3RT1044-1AB04 is a size S3 contactor; the 3RT1036-1AB00 is a different frame size. Footprint and terminal layout differ — panel cutouts and wiring would need to be checked against the respective dimensional drawings. No direct mechanical interchange without verifying rail position and wire routing.

MPN
3RT1044-1AB04