Siemens 3RT1044-1AK60-ZX95 SIRIUS Power Contactor, S3, 37 kW

MPN3RT1044-1AK60-ZX95

Siemens SIRIUS power contactor, size S3, order code 3RT1044-1AK60-ZX95, rated 37 kW at 500 V AC-3, screw-type terminals, snap-on DIN rail mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-1AK60-ZX95 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-1AK60-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-1AK60-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1044-1AK60-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-1AK60-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-1AK60-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-1AK60-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-1AK60-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-1AK60-ZX95 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1044-1AK60-ZX95 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

The main power circuit uses screw-type terminals; stranded cable up to 2x 50 mm² fits the power lugs, so it handles heavy motor feeders without needing an adapter. Solid or ferruled control wiring goes down to 0.5 mm² on the coil/aux terminals.

Operating conditions and endurance

Mechanical endurance is 10 million cycles typical; electrical switching frequency tops out at 1000 operations per hour for AC-1 and AC-3 duty, dropping to 300 per hour for the punishing AC-4 (plugging/inching) category. Arcing time runs 10 to 15 ms, with total make/break time around 10 to 19 ms — fast enough for most motor control circuits.

MPN
3RT1044-1AK60-ZX95