Siemens 3RT1044-3AK60-1AA0 — Contactors

Siemens 3RT1044-3AK60-1AA0 SIRIUS Power Contactor, 37 kW at

MPN3RT1044-3AK60-1AA0

Siemens SIRIUS 3RT1044-3AK60-1AA0 power contactor, size S3, 37 kW at 500 V AC-3, 110 V 50 Hz / 120 V 60 Hz coil, screw terminals, IP20 front, DIN rail mount.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-3AK60-1AA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-3AK60-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-3AK60-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1044-3AK60-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-3AK60-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-3AK60-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-3AK60-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-3AK60-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-3AK60-1AA0 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1044-3AK60-1AA0 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

Integrator's Note — SIRIUS 3RT1044-3AK60-1AA0

The Siemens 3RT1044-3AK60-1AA0 is a SIRIUS power contactor in the size S3 frame, rated for motor switching at 37 kW on a 500 V AC-3 supply — that's the headline figure for conveyor, pump, or fan duty where the load is inductive and the switching frequency is moderate. Coil is dual-frequency rated: 110 V at 50 Hz and 120 V at 60 Hz, with an operating range of 0.8 to 1.1 times the rated voltage at either frequency — so it holds in during brownout conditions down to about 88 V at 50 Hz. Screw-type terminals on the main circuit accept 2x (10 to 50 mm²) stranded cable; auxiliary contacts are rated 10 A at 24 V, stepping down to 0.3 A at 220 V — enough for PLC-level signal switching but watch the DC derating curve if you're breaking inductive DC loads.

Side-by-side mounting is permitted, which keeps the panel width tight; the 70 mm width per unit means a row of four occupies 280 mm of rail space. IP20 on the front with cover or box terminal; the terminal area itself is IP00 — standard for screw-clamp contactors, but plan for a finger-safe cover if the panel is live during maintenance.

At AC-3 duty the maximum switching rate is 1000 cycles per hour, so it handles frequent start-stop cycles on a conveyor without exceeding the thermal limit of the coil.

AC-3 (motor starting) rating is 37 kW at 500 V and 18.6 kW at 690 V — the lower voltage yields higher current capacity, so size the contactor for the line voltage you actually have. AC-1 (resistive heating) maximum switching rate is 1000 cycles per hour; AC-4 (plugging/inching) drops to 300 cycles per hour — the inrush and breaking duty on AC-4 generates more arc energy, so the contactor needs longer cool-down between operations. Auxiliary contact ratings span 10 A at 24 V down to 0.3 A at 220 V, with a 30 W limit at 1000 V — fine for signaling a PLC input or driving a small relay, but not for direct motor control.

Frequently asked questions

What are the key motor ratings for this contactor?

The AC-3 motor rating is 37 kW at 500 V and 18.6 kW at 690 V. The coil is dual-frequency rated for 110 V at 50 Hz and 120 V at 60 Hz.

What wire sizes does the main circuit accept?

The screw-type main terminals accept 2x (10 to 50 mm²) stranded cable, or 2x (2.5 to 16 mm²) solid or stranded. Auxiliary terminals accept 2x (0.25 to 2.5 mm²) solid.

Can this contactor be mounted side-by-side with others?

Yes, side-by-side mounting is permitted. The unit width is 70 mm, so multiple contactors can be ganged on DIN rail without spacing gaps.

What is the operating temperature range?

Operating temperature is -25 to +60 °C; storage temperature is -55 to +80 °C. Pollution degree 3 rating suits industrial environments.

MPN
3RT1044-3AK60-1AA0