Siemens 3RT1044-3AN20-1AA0 — Contactors

Siemens 3RT1044-3AN20-1AA0 SIRIUS Power Contactor, S3, 37 kW

MPN3RT1044-3AN20-1AA0

Siemens SIRIUS power contactor, size S3, 3RT1044-3AN20-1AA0, screw-type terminals, 37 kW at 400 V 50 Hz, 18.6 kW at 690 V, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-3AN20-1AA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-3AN20-1AA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-3AN20-1AA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz220 V
3RT1044-3AN20-1AA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-3AN20-1AA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-3AN20-1AA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-3AN20-1AA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-3AN20-1AA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-3AN20-1AA0 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1044-3AN20-1AA0 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

Rated for 37 kW at 400 V 50 Hz and 18.6 kW at 690 V, this contactor handles the motor starting and stopping duties common on pumps, conveyors, and compressors in a 400 V three-phase line.

The main current circuit uses screw-type terminals, accepting solid conductors 2x (0.25... 2.5 mm²) and stranded 2x (10... 50 mm²). That range covers control wiring up to motor power cables, so you can land both the coil wires and the load conductors without adapters. Switching capacity at 24 V is 10 A, at 230 V is 6 A, and at 400 V is 3 A — these are the contactor's rated operational currents for the main contacts across common control and power voltages. The AC-1 maximum switching rate is 1 000 cycles per hour, AC-3 also 1 000 1/h, while AC-4 (plugging/inching) is limited to 300 1/h, which governs how aggressively you can cycle the load. Arcing time spans 10 to 19 ms at AC, with a narrower 10 to 15 ms window for the arc itself. That's fast enough to limit contact wear in normal motor switching but matters if you're coordinating with upstream protection — the arc clears before the breaker's short-time delay. IP20 on the front with the cover or box terminal installed; the terminal body itself is IP00. That means the front is touch-safe in a closed panel, but the wiring compartment expects enclosure protection — standard for a panel-mounted contactor.

Frequently asked questions

What is the closest functional second-source to 3RT1044-3AN20-1AA0?

The peer 3RT1044-1FB46 is a size S3 SIRIUS contactor with similar ratings, but it uses a different coil voltage or auxiliary configuration — verify the coil rating and terminal layout before substituting into a panel designed around the -3AN20-1AA0.

Will 3RT1044-3AN20-1AA0 drop into a panel specified around 3RT1044-1FB46 without rewiring?

Both are size S3 and share the same mounting footprint on 35 mm or 75 mm DIN rail, so mechanical fit is identical. However, the coil voltage and auxiliary contact arrangement may differ — check the nameplate coil rating before swapping.

MPN
3RT1044-3AN20-1AA0