Siemens 3RT1044-3AP00 — Contactors

Siemens 3RT1044-3AP00 SIRIUS Power Contactor, S3, 37 kW at 5

MPN3RT1044-3AP00

Siemens SIRIUS power contactor, size S3, 3RT1044-3AP00, 37 kW at 500 V AC-3, 55 A at AC-4 400 V, screw-type terminals, snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-3AP00 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-3AP00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-3AP00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1044-3AP00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-3AP00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-3AP00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-3AP00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-3AP00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-3AP00 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1044-3AP00 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

Rated 37 kW at 500 V in AC-3 duty, this contactor handles the heavy lifting on conveyors, pumps, and compressors up to that motor power. The AC-4 rating of 55 A at 400 V covers the inching and plugging cycles that wear out smaller contactors fast. Screw-type terminals on the main circuit accept solid wire 2x (0.25–2.5 mm²) and stranded 2x (10–50 mm²), giving the panel wireman a clear termination range for both control and power feeds.

Lifecycle and compliance — still active, no surprises

Substance prohibited as of 05/01/2012, which aligns with the RoHS compliance date.

The AC-1 maximum switching rate of 1000 1/h tells you this contactor can cycle resistive loads (heaters, lighting) at that pace without overheating the coil or arc chamber. For AC-3 motor switching, the same 1000 1/h rate applies — typical for start-run cycles on a conveyor. AC-4 drops to 300 1/h, reflecting the heavier arc wear from reversing or jogging. Arcing time is 10–19 ms at AC and 10–15 ms for the main contacts — that is the interval the arc extinguishes after the coil drops. It matters for coordination with upstream fuses or breakers: a slower arc can let fault current ride through, but this range is standard for a contactor of this frame. The IP20 front (IP00 at the terminal) means the contactor body is finger-safe once mounted in an enclosure; the terminals themselves need the panel door or a terminal cover for protection. Mechanical life of 10,000,000 operations typical for this class.

Dimensions: 70 mm wide, 146 mm high, 139 mm deep. The auxiliary contact block (not included) plugs onto the front; the coil terminals are screw-type and accept the same wire ranges as the main circuit. For the control wiring, the 2x (0.25–2.5 mm²) solid range covers typical 1.5 mm² control cable.

Frequently asked questions

Will 3RT1044-3AP00 drop into a panel that was specified around 3RT1044-1FB46 without rewiring?

Both are SIRIUS size S3 contactors with the same mounting footprint (70 mm wide, snap-on 35/75 mm rail) and screw-type terminals. The terminal wire ranges are identical, so it is a mechanical and wiring drop-in. The electrical ratings differ — verify the coil voltage and load current match your application.

MPN
3RT1044-3AP00