Skip to main content
Siemens 3RT1044-3AV60 — Contactors

Siemens 3RT1044-3AV60 SIRIUS Power Contactor, 480 V 60 Hz, 3

MPN3RT1044-3AV60

Siemens SIRIUS power contactor, Size S3, 3RT1044-3AV60, 480 V 60 Hz coil, screw terminals, snap-on 35/75 mm DIN rail, 30 kW AC-2 at 400 V.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1044-3AV60 — Identification
ParameterValue
Contactor frame sizeS3
3RT1044-3AV60 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V55 A
Rated value @ 400 V3 A
Rated value @ 500 V37 kW
Rated value @ 690 V18.6 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1044-3AV60 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1044-3AV60 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1044-3AV60 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 125 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1044-3AV60 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1044-3AV60 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1044-3AV60 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1044-3AV60 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1044-3AV60 — Specifications
ParameterValue
At AC10 ... 19 ms

Product details

The 480 V 60 Hz coil matches North American line voltages, and the 30 kW AC-2 rating at 400 V covers wound-rotor or slip-ring motor duty.

For across-the-line starting of standard squirrel-cage motors, the AC-3 capability is the relevant figure; the contactor handles 37 kW at 500 V and 18.6 kW at 690 V. AC-4 reversing or inching duty is rated 55 A at 400 V. Mechanical life is listed at 10 million cycles typical. At the maximum AC-3 switching rate of 1,000 operations per hour, that's over 10,000 hours of continuous cycling — realistic for a conveyor or pump duty that cycles every few seconds.

Wiring and integration

Main circuit terminals accept solid conductors 2x (0.25 to 2.5 mm²) and stranded conductors 2x (10 to 50 mm²) — that covers control wiring through motor power cables up to roughly 70 A. The auxiliary contact block on the front (the 3AV60 variant) is wired separately via the same screw terminals. Dimensions are 70 mm wide, 146 mm high, 139 mm deep — the S3 frame.

Frequently asked questions

How do I get current pricing and availability for 3RT1044-3AV60?

Pricing and stock levels are confirmed at quote time. Submit an RFQ through the storefront; availability and current pricing are provided on request through independent distribution channels.

What is the closest functional second-source to 3RT1044-3AV60?

The peer 3RT1044-1FB46 is a close functional match — same Size S3 frame and similar AC-3 motor ratings — but uses a different coil voltage (not 480 V 60 Hz). Verify coil compatibility before substituting; the 3RT1044-3AV60 is the 480 V 60 Hz variant.

Will 3RT1044-3AV60 drop into a panel specified around 3RT1044-1FB46 without rewiring?

Mechanically yes — both are Size S3 with the same mounting footprint and screw-type terminals. Electrically, only if the coil voltage matches: 3RT1044-3AV60 runs on 480 V 60 Hz, while 3RT1044-1FB46 uses a different coil. If the control circuit supplies 480 V 60 Hz, it's a direct swap.

What compliance documentation does this brand provide for 3RT1044-3AV60?

The part carries a RoHS compliance date of 05/01/2012, indicating compliance with EU RoHS since that date. As a Siemens SIRIUS product, standard documentation includes the manufacturer's declaration of conformity to relevant IEC/EN standards for contactors (IEC 60947-4-1).