Skip to main content
Siemens 3RT1045-1AC24-0AA1-ZX95 — Contactors

Siemens 3RT1045-1AC24-0AA1-ZX95 SIRIUS S3 Power Contactor, 2

MPN3RT1045-1AC24-0AA1-ZX95

Siemens SIRIUS S3 power contactor, 3RT1045-1AC24-0AA1-ZX95, 24 V 50/60 Hz coil, screw-type main circuit terminals, 70 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1045-1AC24-0AA1-ZX95 — Identification
ParameterValue
Contactor frame sizeS3
3RT1045-1AC24-0AA1-ZX95 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V45 kW
Rated value @ 690 V21.1 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1045-1AC24-0AA1-ZX95 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz24 V
3RT1045-1AC24-0AA1-ZX95 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1045-1AC24-0AA1-ZX95 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1045-1AC24-0AA1-ZX95 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1045-1AC24-0AA1-ZX95 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1045-1AC24-0AA1-ZX95 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1045-1AC24-0AA1-ZX95 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth188 mm
3RT1045-1AC24-0AA1-ZX95 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

Its 24 V 50/60 Hz coil matches standard PLC or relay outputs, and the screw-type terminals on the main circuit accept solid conductors up to 4 mm² or stranded up to 50 mm² — enough for the motor power wiring this size handles. This contactor size S3 sits between the smaller S2 and larger S6 frames in the SIRIUS family. The 70 mm width and 146 mm height mean it occupies a standard 35 mm or 75 mm DIN rail slot with room for side-by-side mounting without derating.

The 45 kW rating at 500 V (AC-3 duty) tells you this contactor handles a 3-phase induction motor of that power directly — no external soft-start needed for across-the-line starting. The 21.1 kW at 690 V covers higher-voltage drives or pumps where line voltage steps up. Switching frequency matters for cycling loads: rated at 1 000 operations per hour for AC-3 (motor starting) and 900/h for AC-1 (resistive). For rapid jogging or reversing, the AC-4 limit of 300/h is the one to watch. Auxiliary contact ratings cover the control side: 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V. These are the contacts that signal a PLC input or drive a pilot light — the 24 V rating is the one most integrators will use for feedback to the controller.

Main circuit terminals are screw-type, accepting solid wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). For stranded, it takes 2x (10 to 50 mm²) — that's the range for the motor feeder cables. The front cover carries IP20, meaning finger-safe when closed; the terminal area itself is IP00, so keep live parts behind a panel door.

This order code is the one to specify. No cross-reference to a different frame is needed; the S3 size and 24 V coil are common in European-spec panels.

Frequently asked questions

What are the key dimensions for panel layout?

Width is 70 mm, height 146 mm, depth 188 mm. It mounts on 35 mm or 75 mm DIN rail and can be installed side-by-side without additional spacing.

What wire sizes does the main circuit accept?

Solid wire: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (10 to 50 mm²). All terminals are screw-type.

MPN
3RT1045-1AC24-0AA1-ZX95