Siemens 3RT1045-1AH20 — Contactors

Siemens SIRIUS 3RT1045-1AH20 Power Contactor, S3, 500V 45kW

MPN3RT1045-1AH20

Siemens SIRIUS power contactor, S3 size, 3RT1045-1AH20, 45 kW at 500 V, 21.1 kW at 690 V, screw-type terminals, snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1045-1AH20 — Identification
ParameterValue
Contactor frame sizeS3
3RT1045-1AH20 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V45 kW
Rated value @ 690 V21.1 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1045-1AH20 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1045-1AH20 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1045-1AH20 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1045-1AH20 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1045-1AH20 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1045-1AH20 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1045-1AH20 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1045-1AH20 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

The Siemens SIRIUS 3RT1045-1AH20 is an S3-frame power contactor rated for motor switching at 45 kW on a 500 V 50 Hz line and 21.1 kW at 690 V. That 500 V rating tells you it's sized for a 3-phase motor pulling around 65 A in AC-3 duty — common for medium conveyors, pumps, or compressors in a 400 V to 500 V plant. The 690 V rating covers the 575/600 V class used in North American heavy industrial lines.

The AC-3 switching rate of 1 000 operations per hour is the motor-duty limit — that's about one start every 3.6 seconds, which covers most conveyor and pump cycling. AC-4 drops to 300 per hour, reflecting the higher wear from plugging or inching. If your application needs frequent reversing, that 300/h ceiling is the one to watch. In a normal motor-starting cycle you'll get fewer electrical operations before the contacts wear, but the mechanical figure tells you the solenoid and linkage are built for the long haul. IP20 on the front with the cover or box terminal installed — that's finger-safe for the operator side. The terminal itself is IP00, so the wiring compartment needs enclosure protection in a washdown or outdoor cabinet.

That 50 mm² stranded capacity is generous for an S3 contactor — it lets you land a 2/0 AWG equivalent without a ferrule or pin adapter. The auxiliary contacts handle 10 A at 24 V, 6 A at 230 V, and 3 A at 400 V, which covers most PLC output and relay coil circuits.

Frequently asked questions

What are the key motor ratings for this contactor?

It is rated 45 kW at 500 V 50 Hz and 21.1 kW at 690 V. The coil is 48 V at 50/60 Hz.

What wire sizes does the main circuit accept?

Solid: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded: 2x (10 to 50 mm²).

What is the physical size of this contactor?

Depth 139 mm, width 70 mm, height 146 mm. It mounts on 35 mm or 75 mm DIN rail.