Siemens 3RT1045-1AP08-0MA0 — Contactors

Siemens 3RT1045-1AP08-0MA0 SIRIUS Power Contactor, S3, 70 mm

MPN3RT1045-1AP08-0MA0

Siemens SIRIUS power contactor, size S3, 3RT1045-1AP08-0MA0, 70 mm width, screw-type terminals, IP20 front, snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1045-1AP08-0MA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT1045-1AP08-0MA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V45 kW
Rated value @ 690 V21.1 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1045-1AP08-0MA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1045-1AP08-0MA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1045-1AP08-0MA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1045-1AP08-0MA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1045-1AP08-0MA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1045-1AP08-0MA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1045-1AP08-0MA0 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth188 mm
3RT1045-1AP08-0MA0 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

It mounts on 35 mm or 75 mm standard DIN rails via screw and snap-on fastening, so it integrates directly into a standard panel layout without adapters.

At AC-3 duty (standard motor switching), this contactor is rated for 37 kW at 400 V, which means it handles a typical 37 kW induction motor on a 400 V three-phase line — common for pumps, conveyors, and compressors in industrial plants. At AC-4 duty (inching or plugging), it carries 66 A at 400 V, so it supports reversing or jogging applications where the motor sees repeated start-stop cycles. The AC-1 resistive load rating is not directly stated, but the AC-3 and AC-4 figures give you the motor-duty boundaries. The contactor measures 70 mm wide, 146 mm high, and 188 mm deep, so it occupies a standard S3 footprint on the DIN rail. Side-by-side mounting is allowed, which helps when packing multiple contactors in a row without derating — useful for multi-motor control panels. Terminal capacity covers solid conductors from 0.5 mm² up to 4 mm² (in dual configurations) and stranded conductors from 10 mm² to 50 mm², so it accepts both control wiring and main power cables without adapters.

Frequently asked questions

What conductor sizes does the screw terminal accept?

Solid conductors: 2x (0.5 to 1.5 mm²), 2x (0.75 to 2.5 mm²), max 2x (0.75 to 4 mm²). Stranded conductors: 2x (10 to 50 mm²). Also accepts 2x (2.5 to 16 mm²) solid or stranded.

What is the operating temperature range?

During operation: -25 °C to +60 °C. During storage: -55 °C to +80 °C.

MPN
3RT1045-1AP08-0MA0