Skip to main content
Siemens 3RT1045-3AF04 — Contactors

Siemens 3RT1045-3AF04 SIRIUS Power Contactor, 37 kW AC-2

MPN3RT1045-3AF04

Siemens SIRIUS 3RT1045-3AF04 power contactor, size S3, AC-2 rated 37 kW at 400 V, AC-4 66 A, screw-type terminals, 70 mm width, 188 mm depth.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1045-3AF04 — Identification
ParameterValue
Contactor frame sizeS3
3RT1045-3AF04 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V45 kW
Rated value @ 690 V21.1 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1045-3AF04 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz110 V
3RT1045-3AF04 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1045-3AF04 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1045-3AF04 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1045-3AF04 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1045-3AF04 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1045-3AF04 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth188 mm
3RT1045-3AF04 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

For AC-4 duty (plugging, inching, reversing) at 400 V, the rating is 66 A, which governs the contactor's life under high-stress switching. At 500 V the motor power rating is 45 kW; at 690 V it drops to 21.1 kW. These are the numbers that decide whether this contactor survives the duty cycle on your BOM line.

Termination and Environment

Main power circuit uses screw-type terminals accepting 2x (10…50 mm²) stranded or 2x (0.25…2.5 mm²) solid.

Frequently asked questions

What are the key power ratings for this contactor?

AC-2 at 400 V: 37 kW. AC-4 at 400 V: 66 A. Motor power at 500 V: 45 kW; at 690 V: 21.1 kW.

What compliance documentation is available?

RoHS compliance is documented with a substance prohibition date of May 1, 2012. The part is a Siemens SIRIUS product with standard IEC/UL certification applicable to the series.

MPN