Siemens 3RT1045-3AH00 SIRIUS Power Contactor, 37 kW AC-2 at

MPN3RT1045-3AH00

Siemens SIRIUS power contactor, size S3, 3RT1045-3AH00, 37 kW AC-2 at 400 V, 66 A AC-4 at 400 V, screw-type terminals, 70 mm width, IP20 front.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1045-3AH00 — Identification
ParameterValue
Contactor frame sizeS3
3RT1045-3AH00 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V45 kW
Rated value @ 690 V21.1 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1045-3AH00 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz48 V
3RT1045-3AH00 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1045-3AH00 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1045-3AH00 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1045-3AH00 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1045-3AH00 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1045-3AH00 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1045-3AH00 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

Its AC-2 rating at 400 V delivers 37 kW, which covers the majority of 50–75 hp motor applications at that voltage — the rating that governs motor starting and reversing duty, not just steady-state running.

The AC-3 rating at 500 V is 45 kW, and at 690 V it is 21.1 kW — the voltage-dependent power curve typical of SIRIUS contactors. For a 400 V line, the AC-3 rating is not directly listed in the evidence, but the AC-2 figure of 37 kW at 400 V gives a conservative bound: AC-3 switching is less stressful than AC-2, so the contactor will handle at least that motor power under normal running starts.

The main circuit terminals accept solid conductors from 2x (0.25 to 2.5 mm²) and stranded conductors from 2x (10 to 50 mm²), with an intermediate range of 2x (2.5 to 16 mm²) for either solid or stranded. The auxiliary contact terminals accept 2x (0.25 to 2.5 mm²) solid. The depth of 139 mm, width of 70 mm, and height of 146 mm determine the panel cutout and clearance for the arc chute.

Frequently asked questions

What is 3RT1045-3AH00's listed depth?

The listed depth is 139 mm, with a width of 70 mm and height of 146 mm. These dimensions determine the panel cutout and clearance for the arc chute.

What compliance documentation does this brand provide for 3RT1045-3AH00?

The contactor carries a substance prohibitance date of 05/01/2012, indicating RoHS compliance. As a SIRIUS product, it is designed to meet IEC and UL standards typical for power contactors in this class.

MPN
3RT1045-3AH00