Specifications

3RT1045-3AL20-ZW97 — Identification
ParameterValue
Contactor frame sizeS3
3RT1045-3AL20-ZW97 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V66 A
Rated value @ 400 V3 A
Rated value @ 500 V45 kW
Rated value @ 690 V21.1 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1045-3AL20-ZW97 — Control & Coil
ParameterValue
Control supply voltage typeAC
Rated value @ 50 Hz0.8 ... 1.1
Rated value @ 50 Hz230 V
3RT1045-3AL20-ZW97 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1045-3AL20-ZW97 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1045-3AL20-ZW97 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionspring-loaded terminals
Conductor cross-section, solid2x (0.25 ... 2.5 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.25 ... 1.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1045-3AL20-ZW97 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1045-3AL20-ZW97 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1045-3AL20-ZW97 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1045-3AL20-ZW97 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

Panel integration: the contactor occupies a 70 mm width footprint, 146 mm height, 139 mm depth. The front face is rated IP20 with a cover or box terminal; the terminal area itself is IP00. Pollution degree 3 applies, meaning the contactor tolerates conductive pollution typical of industrial enclosures. Side-by-side mounting is permitted.

Mechanical life typical: 10,000,000 operations. Switching frequencies: up to 900 cycles/hour at AC-1, 400 at AC-2, 1000 at AC-3, 300 at AC-4 (–).

Frequently asked questions

Where can I buy 3RT1045-3AL20-ZW97 and how do I get a price?

This part is sourced to order against an RFQ through independent distribution. Availability and current pricing are confirmed at quote time.

What is 3RT1045-3AL20-ZW97's listed depth?

The depth is 139 mm.

What wire sizes does the solid terminal accept?

The solid terminal accepts 2x (0.25... 2.5 mm²).

MPN
3RT1045-3AL20-ZW97