Skip to main content
Siemens 3RT1046-1AV60-0UA0 — Contactors

Siemens 3RT1046-1AV60-0UA0 SIRIUS Power Contactor, Size S3,

MPN3RT1046-1AV60-0UA0

Siemens SIRIUS 3RT1046-1AV60-0UA0 power contactor, size S3, screw-type terminals, 55 kW at 500 V, IP20 front, snap-on mounting.

Source DocumentedChannel stated on listing & quote
Condition PhotosReal unit photos / video on request
WhatsApp AnswersFast human replies for machine-down parts
Worldwide DispatchDHL/FedEx — transit quoted per order
Independent China distributor & sourcing agent· Listing updated Sep 2026

Specifications

3RT1046-1AV60-0UA0 — Identification
ParameterValue
Contactor frame sizeS3
3RT1046-1AV60-0UA0 — Ratings & Performance
ParameterValue
Rated operational current, AC-12, max.10 A
Rated operational current, AC-4 @ 400 V80 A
Rated value @ 400 V3 A
Rated value @ 500 V55 kW
Rated value @ 690 V25.4 kW
Rated value @ 230 V6 A
Rated value @ 24 V10 A
Rated value @ 60 V2 A
Rated value @ 110 V1 A
Rated value @ 220 V0.3 A
3RT1046-1AV60-0UA0 — Control & Coil
ParameterValue
Control supply voltage typeAC
3RT1046-1AV60-0UA0 — Contacts & Poles
ParameterValue
Main poles3
Main NO contacts3
Auxiliary contact reliability1 faulty switching per 100 million (17 V, 1 mA)
3RT1046-1AV60-0UA0 — Protection & Coordination
ParameterValue
Short-circuit coordination type 1, fusefuse gL/gG: 250 A
Short-circuit coordination type 2, fusefuse gL/gG: 160 A
Aux. switch short-circuit protection, fusefuse gL/gG: 10 A
3RT1046-1AV60-0UA0 — Connection & Mounting
ParameterValue
Main circuit connectionscrew-type terminals
Aux. / control circuit connectionscrew-type terminals
Conductor cross-section, solid2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²), max. 2x (0.75 ... 4 mm²)
Conductor cross-section, solid or stranded2x (2.5 ... 16 mm²)
Conductor cross-section, finely stranded w/ ferrule2x (0.5 ... 1.5 mm²), 2x (0.75 ... 2.5 mm²)
Mounting methodscrew and snap-on mounting onto 35 mm and 75 mm standard mounting rail
Side-by-side mountingYes
3RT1046-1AV60-0UA0 — Durability
ParameterValue
Durability (operating cycles, typ.)10 000 000
Durability with aux. switch block (cycles, typ.)10 000 000
3RT1046-1AV60-0UA0 — Environmental
ParameterValue
Operating temperature range-25 ... +60 °C
Storage temperature range-55 ... +80 °C
Installation altitude, max.2 000 m
3RT1046-1AV60-0UA0 — Mechanical
ParameterValue
Width70 mm
Height146 mm
Depth139 mm
3RT1046-1AV60-0UA0 — Specifications
ParameterValue
At AC10 ... 25 ms

Product details

It carries a 55 kW rating at 500 V, which tells you the motor power it can handle under typical AC-3 duty — the common category for squirrel-cage motors during starting and running. For heavier switching like reversing or inching (AC-4), it is rated 80 A at 400 V, and for AC-2 applications like slip-ring motors, it delivers 45 kW at 400 V. These are the ratings that govern real-world fit, not a single headline number. Side-by-side mounting is supported, which helps when you need to pack multiple contactors in a row without extra spacing.

For solid conductors, it accepts 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²), and up to 2x (0.75... 4 mm²). For stranded conductors, it takes 2x (10... 50 mm²). The auxiliary circuit accepts 2x (2.5... 16 mm²) solid or stranded. This range covers typical motor feeder cables up to 50 mm² stranded, so you can land a 35 mm² or 50 mm² supply cable directly without adapters.

RoHS compliance date is 05/01/2012, so it meets the EU restriction on hazardous substances. The degree of pollution 3 rating aligns with IEC 60947-1 requirements for industrial control gear. No UL or CSA listing is explicitly stated in the evidence, so verify with your local Siemens documentation if your panel requires those marks.

Frequently asked questions

What is the depth of 3RT1046-1AV60-0UA0?

The depth is 139 mm, width 70 mm, height 146 mm. These dimensions fit a standard DIN-rail enclosure with adequate clearance for wiring.

What wire sizes does the 3RT1046-1AV60-0UA0 accept?

For solid conductors: 2x (0.5... 1.5 mm²), 2x (0.75... 2.5 mm²), and up to 2x (0.75... 4 mm²). For stranded: 2x (10... 50 mm²). Auxiliary terminals accept 2x (2.5... 16 mm²) solid or stranded.

Will 3RT1046-1AV60-0UA0 drop into a panel specified for 3RT1044-1FB46?

No, the 3RT1046-1AV60-0UA0 is size S3, while the 3RT1044-1FB46 is a different size class. The mounting hole pattern and terminal layout differ, so rewiring and possibly re-drilling the mounting rail are required.

MPN